Worcester HEATSLAVE 9.24 RSF Installation And Maintenance Instructions Manual page 8

Wall hung combination boiler for central heating and mains fed domestic hot water
Hide thumbs Also See for HEATSLAVE 9.24 RSF:
Table of Contents

Advertisement

Sa.
BOILER FLUE ASSEMBLY
REAR 100
mm
-1000
mm
!4
in.
-
39.3
in.)
NOTE:
A
flue extension kit is
not
required
.
1.
Measure and
cu
t the
air
d
uct t
o
length as
follows:
(a
t Measure
the
wall
t
h~ckne
ss
L
and
add 32 mm
(1
.
25
in.l
See
Fig
.
4
.
This !s
t
he
overall length
of
llOmm 14.5
in
.
1
d
iameter
air duct
required.
(b)
Reo
ucetheai
r du
cttothe
length
required i.e
.
L
+
32mm
I
1 .
25
in
.) by
cutting
the surplus
from t he
plain
end.
Do
not
c ul the expanded
end.
See
Fig.
7.
2.
Fit the
f
lue terminal
adaptor
into
t
he expanded end
ot
the
air
duct.
Slide the
flue
te~minal
into the air
duct
up to
t11~
ro:led
stop
channel
.
Using the holes in the
e;~~;par.deo
end
of the
air
duct
as
a
guide,
drill through the
adaptor
and
f!ue
terminal
w
ith the
3
mm
d
rill suppiied
.
Secure the
assembly
t ogether
with
the two
No.6 x
1
Omm self
tapping
screws.
See
Fig
.
8
.
3.
From the
outside ease
the
air duct
and termina! assembly
through
t he hole prepared in
the wall
.
Ensure
the 8ir duct
engages
in
the
hole
:n
the
wall
mo:.~
rn
i ng
plate
.
It
may
be
necessa~y
to
align
the
hole
in
the
wail
mounting plate
with
t
he
hole
in the
clamping
pfate
by adjusting
the
two
socket
headed
screws
o
n
the
t
op edge of
the
wall
mounting
plate.
See
Fig.
13.
4
.
From
inside adjust
the
air
duct until it
project
s
12
mm
!0.5
in.
l
from
the
fron
t
face of
the
wall
mounting
pi<Jte
.
See
Fig
.
13.
5.
Tigh
t
en
the two screws on
the
too
edge
of
the
wall
m
ou nt
ing
plate
firmly
to
locate
th
e
air
duct.
See
Fig.
13
and
14.
Ensure
t he
air duct is
securely fixed in
position and
the
flue assembly is
in
a
h
orizo
ntal plane.
Make
good
ext
ernal
b
rick
work
or
wall render
ing,
<he
inside
edge
of
the
rolled chan
nel
fixed
to
the
f lue terminal
will prot
rude
approximately
1
Omm
(0.4
in.)
tromthewall
.
See Fig.
13
and
14
.
6
.
Apply
t he sil icone sealant in
a
bead
approximately
6
mm
(0.
2 5
in
.
)
diameter
around
outside of
t
he air
duct and
in
contact
.w
it
h
the
waU moun1ing
plate. See
Fig.
13.
7
.
l
if1
the
appHance
onto the wall
mount
ing plate. Engage
the two
support tabs into the
slots
in
the
back of
t
he
app
liance casing
.
l
ocate t he
t
h
ree
M
6
st
uds
and
air
duct
on
the
wall mounting plate
into
t he back
of
the
appliance
casing.
Fasten the
appliance
to
the wall
mounting p
late
w
it
h
the
t
hree
M6
nuts
and washers
previou sly
removed.
8
.
Rem
ove
the
f
an and fl ue
hood
assembly.
'a
I
Disconnect t
he
electric
a~
connection
t
o the
ian
atthe p lug
in
terminal strip.
(b)
Ease
the fleKible tube
from
t he
left
h
and side
of
t
he fan
housing.
{c) Remove
t
heM
5screw
ho!ding
t he fan
housing
to the
boiler
casing
.
{dl
Slide the
f an
assembly
out
of
t
he
boil
er
casing.
{e
)
Unscrew the two M4 wing nuts
and
washers
one
from
each
s~de
of
t
he f lue hoo
d
assembly.
Ease t he flue hood
assembly
off
the heat
exchanger
and out
of the boiler
casing
.
(f)
Unscrew
the
two M4
extension
wing
bolts
and remove
the
flue duct clamping
ring
1rom
the f lue duct
housing.
9
-
Retain
the
fan assembly and M5
screw,
M4 wing
n u1s
i;ind
washers,
f
lue
hood
assembly,
M4
e>eten
sion w ing
bolts
and clamp ing
rin
g.
T
ake
ca
r
e not
to
damage t
h
e
components
.
10.
Reduce the 60
mm
12.4
in.] diameter Hve
du ct t
o the
required length
which
is
L
+
120
mm
(4. 75
in.
)
NOTE:
Cut
the
surplus
from the
plain
end
.
Do not cut
the
flared
end.
See
Fig.
7
.
1 1
.
Fit
the
f lu
e
duct
clamping
ring
and
f
lue duct
and
replace
t
h
e
f
an
and
flue
hood
assembly as
follow
s
:-
(a) Slide t
h
e
tlue
duct
clamping
ring onto the
f
lue
duct and
·
locate
at t
he
expanded end
of
the
duct
with the
chamfer
aga
inst
the
expanded end
.
See Fig
.
7.
8
lbl
From inside
,
slide
the f lue duct assembly into
t
he
air
duct
engaging
the end of
the flue
duct into the
flue
terminal.
See
Figs.
13
and 14.
·
NOTE:
The
flue
duct
should
slide
into t he
te
rm
inal
approximstely
100
mm {4.0
in
.).
See Fig
.
8
.
fc)
Replace
the
f lue
hood assembly.
Ensure
t he two
M4
bo~ts
are
correctl
y
lo
cated
and
secure w
it
h
the
two
M4
w ing
nut
s
and
washers
previously removed
.
fdl
Assemble
the f lue
duct
to
the
flue
duct
h ousing
and
f
ix
together
w
it
h
t
he
clamping ring and
two
M4
extension
wing
bolts prt!viously
removed
,
See Fig
.
1
3
or
15.
fe)
Replace
t
he
fan
assembly and sccurt: w
i1h
the MSscrew
previously
removed.
li
I
Rep
lacethaflexible
tubeto
t he connection
at the
left-hand
sid
e
of
the
fan
housing.
tg)
Reconnect the
electrical
conr.ec:tior. to
the
fan
at
t
he
p!ug
in
termin
al
strip
.
12.
Complete
the rema
inder
of
t
he
in
stallation as detailed in
Section
8
.
pa ragraph
1
5
o
nwards
.
8b.
BOILER FLUE ASSEMBLY
REAR 1001
mm
-
1200mm
!39.3
in.
-
47.2
in.l
NOTE: For
flue
length 1001 mmto
1200
rnm t39.4in.
to4
7.2
in .)
use
th~
star,darci flue
assembly and
extension
fl ue.
1
.
Cut and
assemble
the air
duct
as
1oll
ows:-
(a)
MMsurP
the
flue
length land
ad
d 32 m
m
(
1.
25
in.
)
See
Fig. 14.
This
is
t
he
overall
lengt
h
of
1
10
mm (4
.
5 in.
!
diam
eter air duct requ
ired.
(b) Reduce
the
lengt
h
of
t
he
st
andard air duct to
900
mm
(35.5in.}.
Cut
surplus
f
rom
plain
end
.
Donotc:utexpanded
end.
See
Fig.
9
.
(c
l
Reduce the
length
of
th
e
extension
air
duct
by cutting from
t
he
end w
ithout
holes
until t
he required
over
aU
length after
engagement
of
t
h
e
two
d
ucts
is
obtained.
See
Fig.
9.
ldl
FuHy enga9e
the
e;~~;tension
air
duct
into
the
expanded
end
of
the shortened
st
andard
air
duct.
Ensu
re
t
he
ovcr~ll
length
is
co~rec
t
and
the
two
holes
in
the
extension
air duct
are posi
t
ioned
at
the
e;~~;treme
end. See
Fig.
9.
(e)
Using
t
he two hole
s in
the
expanded
end
as
a
guide
,
d
rill
two
3
mm diameter h oles us
ing
the
dr
ill
supplied.
Disengage
the air ducts
and
apply a smear
ot siticone
sea lant around t he o
utside
of
tht:
exten
sion
duct
.
Reassemble and
secu
re
with
t he two
self
·tapping
screws
suppfied
.
See Fig
.
9.
2
.
Stide t
ile
flue
t
erminal
into
t
he e)(t
ension
air
duct up
t
o t
ile
rolled
stop
channel.
NOTE:
The flue
t erminal
adaptor
is not required and
must
be
d
iscarded.
Using
the
holes
in
t
he
eKtension
air
du ct
as a
guide,
drill
through
t
he f lue
terminal
with
t
he
3mm
drill
supplied
.
Securetheassembly
togethet
wit
h
t
he
two
No.
6
;~~;
10mm
self
tapping
!>crews.
See
Fig.
l
0
.
3
.
From
t
he
outside
ease
the
air
duct
and
terminal
assem
bly
th
rough t
he
hole
prepared
in
t
he
wall.
Ensure the air
duct
eng ages
in
the tlole
in
the
wall
mounting
plate
.
It
may
be
necessary
to
align the
hoi~
in
the
wall
mounting
plate
with
the
hole in
t
he
clamping
plate
by
adjusting t
he
t
wo
socket
headed
screws
on
the top
edge
of
t he
wall
mounting
plate.
See
Fi
g.
13
.
4
.
From
inside,
adjust
t
he air duct
until
it
projects
1
2
m
rn
(0
.
5
in.)
f
rom
the
front
face
o
f
the wall
mounting pl at e.
See
Fig
.
1
3.
5
.
T ighten
t
he
two screws
on
the
top edg
e
of the
wall
mounting plate firm ly to locate
t
he air
duct.
See
Fig.
1
3
and
14.
Ensure
the
air
duct
is securely fixed
in
posit
ion
and
the flue assembly is in a
horizontal
plane. Make go od
external
brickwork or
wall
re nd
ering,
the
ins
ide
edge
of
the
rolled
chan
nel
f
i
xed
to
t he flue te
rminal
will
protrude
app
roximatley
1 Omm
(0.4
in
.)fromthe
wall.
See
Fig.
13
and
14.

Advertisement