Tx Port Settings - Victron energy SmartSolar MPPT 250/70 Manual

Mppt solar charger
Hide thumbs Also See for SmartSolar MPPT 250/70:
Table of Contents

Advertisement

The Mid-point shift setting is only relevant when your streetlight setting program uses "Midnight" as a
switching moment.
Calculation Example:
For calculation we use a day of 1440 minutes, where Sunset is at 19:00 (1140 minutes) and Sunrise is at 6:25 (385 minutes):
• The night duration in minutes is: 1440m
• The degree of shift = time of sunset
42 minutes.
Example configuration
The selections which have been made on above screen image results in this program:
• At sunset - the light will be switched on for a fixed time.
• Dim level at sunset - at Full brightness (100%).
• Keep lights on during - the duration has been set to 1h 0m.
• Dim level at end - at the end of one hour the brilliance will be reduced to half (50%).
Also:
• At sunrise - the lighting will be adjusted before sunrise.
• Time before sunrise - at 1h 0m before sunrise, the following adjustment will be made:
• Dim level - full brilliance will be restored (100%).

5.2.5. TX port settings

The VE.Direct-TX port can be used to send a signal to an external device. For example, to send a PWM signal to dim a
streetlight.
To use the TX port, a
VE.Direct TX digital output cable
Page 29
MPPT solar charger manual
(min/day)
-1140m(time to sunset) + 385m
(minutes)
+ half the duration of night
is needed.
(time to sunrise)
= 685m.
(minutes)
(minutes)
- length of day
= 1140m + 342m - 1440m =
Configuration and settings