• At sunrise - the lighting will be adjusted before sunrise.
• Time before sunrise - at 1h 0m before sunrise, the following adjustment will be made:
• Dim level - full brilliance will be restored (100%).

5.2.4. TX port settings

The VE.Direct-TX port can be used to send a signal to an external device. For example, to send a PWM signal to dim a
streetlight.
Be aware that changing away from the default setting while a
need to be removed and the load output algorithm has to be configured via the
setting [21]
instead.
To use the TX port, a
VE.Direct TX digital output cable
The functionality of the TX port can be set at:
• Normal communication:
This is the default setting. Use this function when connecting to a GX device, a VE.Direct Bluetooth Smart dongle, or any other
device that needs to communicate with the solar charger via the VE.Direct port.
• Pulse every 0.01 kWh:
Use this function in combination with an energy meter.
The TX port will emit a pulse each time an additional 0.01kWh of energy has been harvested. The TX port is normally high and
will be driven low for approximately 250ms for every 0.01kWh harvested.
• Light dimming (PWM normal):
Use this function in combination with the "Streetlight" setting.
*
The TX port PWM
signal will be at 100% duty cycle when full light intensity is required.
• Light dimming (PWM inverted):
Use this function in combination with the "Streetlight" setting.
*
The TX port PWM
signal will be at 0% duty cycle when full light intensity is required.
• Virtual load output:
Use this function to create a virtual load output for loads that draw more current than the load output is rated for.
The TX port will switch using the same conditions as set in the load output settings.
Connect the VE.Direct TX digital output cable to a BatteryProtect module, a relay or directly to the remote on/off connector of
**
the load
.
*) The PWM signal is 5V, 160Hz.