G.703-To-G.703 Configuration - Paradyne HotWire 7925 User Manual

Standalone e1 hdsl termination unit
Hide thumbs Also See for HotWire 7925:
Table of Contents

Advertisement

Worksheets

G.703-to-G.703 Configuration

A-2
To connect two G.703-compatible units, configure the units as follows (factory
defaults are in bold):
Configuration
G.703-Compatible Unit
Option
(Customer Premises)
Card Type
CP (default)
Loops Enabled
Dual (Loops A & B) or
Single (Loop A)
E1 Line Encode
HDB3 or AMI
Framing
Framed or Unframed
(If payload rate is less than
2048 kbps, select Framed;
else select either option)
1
Line Build-Out
75 ohm or 120 ohm
1
Jumpers C31, C33, P6, and P7 must be manually changed to match the configured
line build-out rate. See
Changing the Line Build-Out
June 1997
G.703-Compatible Unit
(Central Site)
CO
Must be same as CP side
Must be same as CP side
Must be same as CP side
75 ohm or 120 ohm (does not need
to be the same as the CP side)
in Chapter 4 for instructions.
7925-A2-GB20-30
PRELIMINARY DRAFT