Monitoring the Unit

Board Status

Board Status option from the Main Menu displays HDSL circuit operational status.
Enter 1 at the Command prompt to display board status.
Board Status for G.703-Compatible Unit
Board Status for V.35-Compatible Unit
6-2
Command
1
E1 STATUS:
Network is UP
LOOPBACK STATUS: OFF
HDSL STATUS:
LOOP A is UP, LOOP B is UP
S/N RATIO:
Loop A = 44.0 dB, Loop B = 43.5 dB
Command
Command
1
DTR:
ACTIVE
DSR:
ACTIVE
LOOPBACK STATUS: OFF
HDSL STATUS:
LOOP A is UP, LOOP B is UP
S/N RATIO:
Loop A = 44.0 dB, Loop B = 43.5 dB.
Command
E1 status displays one of the following: Network is Up, Receive Carrier Loss,
Receive Remote Alarm, or Receive Unframed All 1's.
DTR and DSR are either active or inactive. DSR becomes active in response
to DTR (with HDSL loops up and data transmission possible).
Loopback status is either ON or OFF.
HDSL status displays whether each loop is up, down, or disabled.
Signal-to-Noise (S/N) ratios do not display if loops are down or disabled.