Displaying Line Build-Out Definitions - Paradyne HotWire 7925 User Manual

Standalone e1 hdsl termination unit
Hide thumbs Also See for HotWire 7925:
Table of Contents

Advertisement

Customizing G.703-Compatible Units

Displaying Line Build-Out Definitions

Enter 7 at the Config prompt to display the switchpack and board settings for line
build-out. This information is useful if you need to change the line build-out
parameter manually. Refer to Changing the Line Build-Out on page 4-4 for more
information.
Line build-out selects a transmit wave form compatible with the chosen
termination impedance (75 ohm or 120 ohm).
4-6
Config
7
*****
SWITCHPACK AND BOARD SETTINGS FOR LINE BUILD OUT
Switchpack Setting
–––––––––––––––––––––––––
Position #5
OFF=75 ohm
ON=120 ohm
Command
June 1997
Jumpers P6 and P7 on Stand Alone
Jumpers P4 and P5 on Shelf Mount
–––––––––––––––––––––––––––––––––
1 & 2 for 120 ohm lines
2 & 3 for 75 ohm lines
*******
7925-A2-GB20-30
PRELIMINARY DRAFT