Pump DELTA VM1LR2
Viscosity
Oil temperature
Inlet pressure
Return pressure
Suction height
Rotation speed
Pump DANFOSS BFP21L3
Viscosity
Oil temperature
Inlet pressure
Return pressure
Suction height
Rotation speed
Key
1
Pressure setting
2
Manometer
3
Vacuometer
4
Solenoid valve
5
Nozzle
7
Inlet
8
Return
AIR RATE SETTING
Fig. 15
VBS
Type G4 mod. G-.TN...N.x and
G-.TN...S (internal air setting)
Slacken the screw VBS.
The air rate is set moving the screw
VBS through the slot.
At the end of settings tight the screw
VBS.
10
2 - 50 mm²/s (cSt)
0 - 60 °C in the pump
2 bar max.
2 bar max.
0,5 bar max. to avoid air separation
from oil
3500 rpm max.
1.3 - 12 mm²/s (cSt)
70 °C in the pump
2 bar max
2 bar max
0,35 bar max. to avoid air separation
from oil
3600 rpm max.
Fig. 16
VBS
Type G4 mod. G-.TN.x.*.A.x (external air
setting)
Set the air rate rotating the screw VBS.
PART I: INSTALLATION MANUAL
Fig. 13
Fig. 14
Fig. 17
Type G6 - G10 - G18
Slacken the screw VBS and
rotate manually the air damper
as needed.
At the end of settings tight the
screw VBS.
VBS