Manual for installation of the Sensformer® Connectivity Device
Digital registers:
Name
Length (bit)
Value
Pulse count
Pulse width
Timestamp
Table 22 – Response to the request of digital registers
Request (channel 1):
00 01 00 00 00 06 01 04 01 90 00 05
Transaction ID:
00 01
Protocol ID:
00 00
Length:
00 06
Unit ID:
01
Function code:
04
Address:
01 90
Quantity of register:
00 05
Response:
Transaction ID:
00 01
Protocol ID:
00 00
Length:
00 0d
Unit ID:
01
Function code:
04
Len:
0a
Data:
00 00 00 00 00 00 5d 1d e9 f3
value: 0 (00 00)
pulse count: 0 (00 00)
pulse width: 0 (00 00)
timestamp: 1562241523 (5d 1d e9 f3), date-time format: 2019.
July 4. 13:58:43
Type
16
integer
16
integer
16
integer
32
integer
© 2020 Siemens Energy
Location:
Name
Length (bit)
Latitude
Longitude
Timestamp
Table 23 - Response to the request of location
Request:
00 01 00 00 00 06 01 04 02 58 00 06
Transaction ID:
00 01
Protocol ID:
00 00
Length:
00 06
Unit ID:
01
Function code:
04
Address:
02 58
Q. of reg.:
00 06
Response:
00 01 00 00 00 0f 01 04 0c 42 3e 1b 82 41 98 9c be 5d 23 37 94
Transaction ID:
00 01
Protocol ID:
00 00
Length:
00 0f
Unit ID:
01
Function code:
04
Len:
0c
Data:
42 3e 1b 82 41 98 9c be 5d 23 37 94
latitude: 47.52686 (42 3e 1b 82)
longitude: 19.07653 (41 98 9c be)
timestamp: 1562589076 (5d 23 37 94), date-time format: 2019.
July 8. 14:31:16