Summary of Contents for Siemens Milltronics ILE-37
Page 1
While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied. Overview: To replace the diaphragm on a Milltronics ILE-37, please follow the directions below. Part One: Step Four Part Two: Step Three...
Page 2
Step Three: Remove Bushing Lock Nuts Use 1 ¾" or 45 mm wrench, or adjustable wrench to Remove protective plastic ring. remove the two bushing lock nuts, one at a time. Milltronics ILE-37 Sensing Head Diaphragm Replacement AG050425 2 of 7...
Page 3
Step Five: Separate Inner Diaphragm Ring from ILE-37 Body Use 5 mm Allen key to remove the four screws connecting the inner diaphragm Separate the inner diaphragm ring ring to the ILE-37 body. from the ILE-37 body. Milltronics ILE-37 Sensing Head Diaphragm Replacement AG050425 3 of 7...
Page 4
ILE-37 body. Line up the holes of the new diaphragm with the holes on the ILE-37 body. Milltronics ILE-37 Sensing Head Diaphragm Replacement AG050425 4 of 7...
Page 5
Line up holes on LVDT conditioner card with the the LVDT conditioner card. holes of the spacers. Use 2.5 mm Allen key to replace the two screws. CAUTION: Do not touch circuitry on LVDT conditioner card Milltronics ILE-37 Sensing Head Diaphragm Replacement AG050425 5 of 7...
Page 6
Use 5 mm hex screwdriver or Allen key to tighten the set screw. roll pin CAUTION: Do not use hammer or excessive force! Milltronics ILE-37 Sensing Head Diaphragm Replacement AG050425 6 of 7...
Page 7
Line up the holes of the fiberglass cover with the the fiberglass cover to the unit. holes in the main body. Use 6 mm hex screwdriver or Allen key to tighten the four screws. Milltronics ILE-37 Sensing Head Diaphragm Replacement AG050425 7 of 7...