Special Requirement for Safe Use
WARNING - EXPLOSION HAZARD. DO NOT CONNECT OR DISCONNECT WHEN ENERGIZED
AVERTISSEMENT - RISQUE D'EXPLOSION. NE PAS BRANCHER NI DÉBRANCHER SOUS TENSION
WARNING - POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS
AVERTISSEMENT - ÉLECTROSTATIQUE POTENTIEL RISQUE DE CHARGE - VOIR LES INSTRUCTIONS
WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
AVERTISSEMENT - NE PAS OUVRIR LORSQUE UN EXPLOSIF L'ATMOSPHÈRE EST PRÉSENTE
The connections on this equipment are not intended to be connected or disconnected when an explosive
atmosphere is present.
Only EX-certified personnel are allowed for on-site installation and electrical connections of equipment.
Manual switch TPS3851H18EDRBR is protected by at least an IP66 enclosure, it is not allowed to operate the
switch in a hazardous area.
Type-C USB port is protected by at least an IP66 enclosure, and it is not allowed to be used in hazardous area.
Wipe with a wet cloth and use PPE for routine maintenance.
Required protection shall be applied to avoid the high risk of mechanical damage occurred by the final
installation.
Use cable gland, stopping plug, conduit fitting or similar device with ingress of protection of IP66, and the
installation shall meet the requirements of CEC (for Canada) and NEC (for USA) for wiring method in Division
2 and is subjected to acceptance of local authorities having jurisdiction.
The equipment must be installed and used in an area of at least pollution degree 2, as defined in IEC 60664-1.
Only ATEX/IECEx certified cable glands as specified in the instructions are to be installed and used on the
enclosure, and IEC/EN 60079-14 shall be observed when installing. Suitable type of protection cable gland to
be selected with spec: M20x1.5 with minimum IP66 rating. Unused cable entry ports to be blocked by Ex
plugs with minimum IP66 rating.
Earthing system shall be finished in accordance with user manual before use.
Damaged Protective Vents have to be replaced immediately.
The products have been evaluated for use at altitudes not exceeding 3000 m.

Standard Compliance

EN IEC 60079-0:2018
EN IEC 60079-7:2015/A1:2018
EN 60079-31: 2014
IEC 60079-0:2017 Edition 7.0
IEC 60079-7:2015+A1:2017 Edition 5.1
IEC 60079-31:2022 Edition 3.0
CSA C22.2 No.213-17
UL 121201 Ninth Edition
ATEX Certificate Number and Marking
TÜV 21 ATEX 8711 X
HPE Aruba Networking 580EX Series Hazardous Location Outdoor Access Points
Regulatory Model Number
https://certificates.ext.hpe.com/public/certificates.html
| Installation Guide
section of this document] is in
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ap-585exAp-587ex

Table of Contents