4. Insert the connector of the fiber-optic cable into the transceiver module, and ensure the connector is firmly
in place.
5. Screw the SFP extension tube into the E1 SFP+ port and tighten to a torque of 88 in/lbs (10 Nm).
6. Place the O-ring on the gland body, and ensure it is in place.
7. Thread the gland body into the SFP extension tube and tighten to a torque of 70.5 in/lbs (8 Nm).
8. Push the seal B and seal A into the gland body and tighten the sealing nut onto the gland body to a torque of
53in/lbs (6 Nm).
For more details on the 20A2F cable gland such as conditions of use, installation instructions and technical
data, please refer to CMP website:
https://www.cmp-products.com/Installation%20Instructions/CMP%20A2F.pdf
Figure 9

Connecting the AC Power Cable

Best Practice for Outdoor Connection to AC Mains
In all circumstances and with any outdoor infrastructure the recommended practice is to connect to AC mains in
an outdoor grade weather protected junction box. This needs to be implemented by a qualified resource in a
manner that is consistent with the electrical code in force in the jurisdiction of deployment. In many countries
this will require a licensed electrician to perform this operation. In Japan, this would be performed by a Certified
Electrician by Ministry of Economy, Trade and Industry.
The use of plugs with infrastructure equipment is suitable only for temporary installs where nuisance tripping of
GFI plugs is considered tolerable. if a plug is desired for attachment to the cable assemblies then the installer is
expected to follow all directions provided with the plug end in a fashion consistent with local electrical code.
!
The 580EX Series access point does not ship with any AC power cables. HPE Aruba Networking offers an AP-AC-
MLX-EX outdoor Molex AC connector kit (sold separately) for customers to assemble their own AC power cable
and connect the AC power cable to the AP. For installation instructions, refer to the AP-AC-MLX-EX AC Connector
Kit Installation Guide shipped with the AP-AC-MLX-EX kit.