Maintenance, Service, And Storage - Falltech DuraTech SRL-R User Instruction Manual

Class 1 3-way retrieval
Table of Contents

Advertisement

5.7.4 Inspect the Cable:
The SRL-R lifeline is galvanized steel cable/wire rope, and subject to certain hazards. Inspect the lifeline
before each use for the conditions as described in Section 7.
5.8 Using the SRL-R:
Do not use the SRL-R if inspection shows damage or any malfunction. Don the FBH in accordance
with the FBH manufacturer's instructions. Follow the instructions contained in this manual and on
the labels. Failure to follow instructions may result in serious injury or death. Connect the leg end
snap hook to the dorsal D-ring on the FBH. Ensure the carabiner closes and locks. Attach the housing
carabiner to the chosen anchorage and ensure the carabiner closes and locks. Ensure all connections
are compatible. Normal operation will allow the working length of the lifeline to extend and retract as
the worker moves about. A certain amount of tension must remain on the cable at all times to ensure
proper operation of the internal brake. Do not allow the lifeline to have slack. If the lifeline does not
retract, remove the SRL-R from service for inspection. See Section 7.
Avoid sudden or quick movements during the normal work operation, as this may cause the SRL-R
brake to engage and possibly cause loss of balance which may result in injury or death.
If a fall occurs, the brake will engage and lock the lifeline to arrest the fall and limit arrest forces on the
user.
DO NOT extend the lifeline past the operational limit.
DO NOT allow one SRD lifeline to become tangled or twisted with another SRD lifeline during use.
DO NOT allow any lifeline to pass under arms or between legs during use.
DO NOT clamp, knot, or prevent the lifeline from retracting or being taut.
DO NOT lengthen the SRD by connecting a lifeline or similar component.
DO NOT allow the lifeline to remain outside the housing when not in use.
DO NOT allow the lifeline to freewheel back into the housing. Use a tag line to maintain tension
and rewind the lifeline during periods of inactivity. Use the tag line to retrieve the leg end
connector for the next use.
DO NOT leave the tag line connected to the leg end connector when using the SRD for fall
protection.
5.9 After A Fall:
A fall event over an edge may require special rescue equipment and measures. Ensure a written
rescue plan, method and system is in place and readily available to all users for rapid response. Ensure
all users are trained in rescue procedures. If a fall event occurs, remove it from service, and store it
separately. Remove from service any unit that has been subjected to fall arrest forces or that exhibits
damage consistent with such forces. For questions, contact FallTech.

6.0 Maintenance, Service, and Storage

6.1 Maintenance:
Ensure the SRL-R is kept free of excess paint, grease, dirt or other contaminants as this may cause to
cable or retracting mechanism to malfunction. Ensure no debris enters the housing through the cable
access port. Clean the exterior of the unit as required with a detergent/water solution. Avoid water
other corrosion causing elements to enter the housing. After cleaning, pull the lifeline all the way out,
allow the unit to air dry, then retract the lifeline into the unit. Do not allow the lifeline to freewheel back
into the housing. Clean labels as required.
DO NOT use heat to dry.
DO NOT attempt to disassemble the SRD.
6.2 Service:
If service is required for any reason; inspection failure, impact loaded, any type of malfunction, tag
the unit as "UNUSABLE", store separately, and contact FallTech at 323-752-0066 to receive a Return
Authorization number or to locate the nearest FallTech Service Center. The SRL-R is not user repairable.
Only the manufacturer, or a repair facility authorized in writing, may make repairs to the SRL-R. This
SRL-R is designed to be used installed in an anchor cradle or attached overhead.
6.3 Storage:
Hang the SRL-R in a cool, dry, clean environment out of direct sunlight. Position the SRL-R so excess
water can drain out. Avoid exposure to chemical or caustic vapors. Thoroughly inspect the SRL-R after
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

72777278

Table of Contents