Download Print this page

Peco WA721FSs Installation & Operation Manual page 8

Wraparound front straight

Advertisement

WRAPAROUND FRONT STRAIGHT (Stainless Steel)
3/8" POLY FLOW LINE
1. Mount the bracket to the wall in Equipment Room using the provided 5/16" x 1-
1/2" anchors. This unit should be as close as possible to the tunnel equipment it
is supplying.
2. Connect a 3/8" polyflow air supply line to the push-lock fitting at the control
regulator gauge
3. Port 'A' must be plugged with the supplied ¼" fitting.
4. Run 3/8" polyflow line out to the air cylinders on the boom arms. The line must
be teed to feed the driver and passenger side air cylinders. The air pressure to
these cylinders is used to push the arms to the retract position when the 4-way
valve is de-energized.
5. Connect the electric power supply to the solenoids from the designated terminal
in the tunnel controller. Check label on solenoid coil to verify control voltage.
Connecting the wrong voltage will damage the unit.
PECO Corporation – 244 Rex Boulevard – Auburn Hills – Michigan – 48326 – USA – 1-248-299-5800
07/14/23
S:\Engineering Doc's\Manuals & Packing Lists Combined\WRAP WASHERS\997206 WA721FSs_V2.doc
4W1 VALVE AIR CONTROL
REMOVE ELBOW
FITTING AND REPLACE
WITH SUPPLIED PLUG
USE 3/8" POLY FLOW
TO CONNECT TO
D/S & P/S AIR
CYLINDER TO PUSH
THE ARMS AWAY
FROM THE VEHICLE.
AIR PLUMBING SCHEMATIC
www.PECOCARWASH.com
4W1 VALVE
COIL
A
P
B
AIR REG
CLEAN,
DRY AIR
FROM
COMPRESSOR
TEE LINE
SHORT POLY FLOW
TUBE LEFT OPENED
TO ATMOSPHERE TO
REDUCE MOISTURE
INTAKE.
990372AY57
Page 8 of 33

Advertisement

loading

This manual is also suitable for:

997206