6.1.9 Other Approvals; Emc And Environmental Type Tests - RuggedCom SIMATIC NET RS416PF Equipment Manual

Rugged ethernet switches
Table of Contents

Advertisement

Certification
6.1.9 Other Approvals
6.1.9
Other Approvals
This device meets the requirements of the following additional standards:
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS416PF has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
61000-4-2
61000-4-3
61000-4-4
61000-4-5
61000-4-6
44
IEEE 1613
IEEE Standard Environmental and Testing Requirements for Communications
Networking Devices in Electric Power Substations
IEC 61850-3
Communication Networks and Systems for Power Utility Automation - Part 3:
General Requirements
IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity
for Industrial Environments
Test
IEC
ESD
IEC
Radiated RFI
IEC
Burst (Fast Transient)
IEC
Surge
IEC
Induced (Conducted) RFI
Description
Enclosure
Contact
Enclosure Air
Enclosure
ports
Signal ports
DC Power
ports
AC Power
ports
Earth
ground ports
Signal ports
DC Power
ports
AC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Earth
ground ports
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
2 kV
± 2 kV line-to-earth,
± 1 kV line-to-line
± 4 kV line-to-earth,
± 2 kV line-to-line
10 V
10 V
10 V
10 V
RUGGEDCOM RS416PF
Equipment Manual, 10/2023, C79000-G8976-1355-07
Severity
Levels
4
4
a
Note
a
Note
4
4
4
3
3
4
3
3
3
3

Advertisement

Table of Contents
loading