PI P-750 User Manual

PI P-750 User Manual

High-load piezo-driven nanopositioner with direct position measuring

Advertisement

Quick Links

User Manual
P750UM0001, applies to P-750.20
CBo, 1/26/2024
P-750
High-Load Piezo-Driven Nanopositioner with Direct Position Measuring
Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany
Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws,
www.pi.ws

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P-750 and is the answer not in the manual?

Questions and answers

Summary of Contents for PI P-750

  • Page 1 User Manual P750UM0001, applies to P-750.20 CBo, 1/26/2024 P-750 High-Load Piezo-Driven Nanopositioner with Direct Position Measuring Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws, www.pi.ws...
  • Page 2: Table Of Contents

    Maximum Ratings .............................. 23 Ambient Conditions and Classifications ......................23 Dimensions ................................ 24 Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany Page 2 / 26 Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws,...
  • Page 3 Torque for Stainless Steel Screws (A2-70) ......................25 Pin Assignment ..............................25 Old Equipment Disposal Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany Page 3 / 26 Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws,...
  • Page 4: About This Document

    It assumes that the reader has a fundamental understanding of basic servo systems as well as motion control concepts and applicable safety procedures. Explanation of Symbols This section explains the symbols and markings used by PI in this user manual. Typographic Conventions Symbol...
  • Page 5: Other Applicable Documents

    Safety Intended Use The P-750 is a laboratory device as defined by DIN EN 61010-1. It is intended for indoor use and use in an environment that is free from dirt, oil, and lubricants. According to its design, the P-750 is intended for fine positioning as well as moving small objects quickly and precisely.
  • Page 6: Safety Precautions

    If the protective earth conductor is not or not properly connected, dangerous touch voltages can occur on the P-750 in the event of malfunction or failure of the system. If there are touch voltages, touching the P-750 can result in minor injury from electric shock.
  • Page 7: Product Description

    Manufacturer's address (website) CE conformity mark Symbol for the protective earth conductor (p. 10) Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany Page 7 / 26 Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws,...
  • Page 8: Scope Of Delivery

    2 flat washers  PZ240EK Short instructions for P-5xx / P-6xx / P-7xx piezo positioners Suitable Electronics To operate the P-750, you need suitable electronics. Selection of the device depends on the application and the connectors available. Electronics Connector Channels E-500 •...
  • Page 9: Unpacking

     Do not let screw heads protrude.  Only use the holes or threads intended for the purpose of fixing the P-750 and loads.  Pay attention to the torque range (p. 25) specified for the screws used during installation.
  • Page 10: Connecting The P-750 To The Protective Earth Conductor

    P750UM0001, applies to P-750.20 CBo, 1/26/2024 INFORMATION Extension cables can reduce the positioning accuracy of the P-750 or affect sensor processing by the electronics.  Do not use extension cables. If you need longer cables, contact our customer service department (p. 21).
  • Page 11: Mounting The P-750 Onto A Surface

    Mounting the P-750 onto an uneven surface can warp the P-750. Warping reduces the accuracy.  Mount the P-750 onto a flat surface. The recommended flatness of the surface is ≤10 µm.  For applications with large temperature fluctuations: Only mount the P-750 onto surfaces that have the same or similar thermal expansion properties as the P-750 (e.g., surfaces made of steel).
  • Page 12  You have read and understood the general notes on installing (p. 9).  The P-750 is not connected to the electronics. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany Page 12 / 26 Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws,...
  • Page 13: Fixing The Load

     Mounting the P-750 onto a surface 1. Align the P-750 so that the mounting holes in the P-750 are in line with the mounting holes in the surface. 2. Insert the mounting screws through the countersunk mounting holes in the P-750’s base body into the surface from above.
  • Page 14 If the center of load is located too far away from the center of the motion platform (e.g., tall loads and unwanted lever effect), the P-750 can be damaged by high strain on the flexure guides, high torque, and oscillation, especially when operated dynamically.
  • Page 15 − thermal expansion properties as the P-750 (e.g., load made of steel). Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany Page 15 / 26 Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws,...
  • Page 16: Connecting The P-750 To The Electronics

    1. Align the load on the P-750’s motion platform so that the corresponding mounting holes in the load and in the motion platform are in line. 2. Insert the screws through the holes in the load into the mounting holes in the P-750’s motion platform.
  • Page 17: Startup And Operation

    If the protective earth conductor is not or not properly connected, dangerous touch voltages can occur on the P-750 in the event of malfunction or failure of the system. If there are touch voltages, touching the P-750 can result in minor injury from electric shock.
  • Page 18 Short-circuiting due to condensation! Condensation can lead to short-circuiting and failure of the P-750.  Wait for a sufficient period of time to allow the P-750 to reach room temperature in the following cases: After unpacking or before starting for the first time −...
  • Page 19  Recalibrate the axis displacement (refer to the controller manual) or contact our our customer service department (p. 21). INFORMATION Sound and vibration (e.g., footfall, knocks) can be transmitted to the P-750 and can affect its performance with regard to position stability.  Avoid sound and vibration while the P-750 is being operated.
  • Page 20: Starting And Operating The P-750

     You have read and understood the general notes on starting (p. 17).  You have installed (p. 9) the P-750 correctly and connected it to the electronics (p. 16).  You have read and understood the user manual for the electronics.
  • Page 21: Maintenance

    Requirements  You have disconnected the P-750 from the electronics. Cleaning the P-750  When necessary, clean the surfaces of the P-750 with a cloth that is dampened with a mild cleanser or disinfectant (e.g., isopropyl alcohol). Customer Service For inquiries and orders, contact your PI sales engineer or send us an email (service@pi.de).
  • Page 22: Technical Data

    The resolution of the system is limited only by the noise of the amplifier and the measuring technology because PI piezo nanopositioning systems are free of friction. Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany Page 22 / 26 Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws,...
  • Page 23: Maximum Ratings

    Degree of pollution Degree of protection IP20 according to IEC 60529 Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany Page 23 / 26 Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws, www.pi.ws...
  • Page 24: Dimensions

    P750UM0001, applies to P-750.20 CBo, 1/26/2024 Dimensions Figure 9: P-750.20, dimensions in mm Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany Page 24 / 26 Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws, www.pi.ws...
  • Page 25 Piezo voltage Piezo voltage ground on cable shield Physik Instrumente (PI) GmbH & Co. KG, Auf der Römerstraße 1, 76228 Karlsruhe, Germany Page 25 / 26 Phone +49 721 4846-0, fax +49 721 4846-1019, e-mail info@pi.ws, www.pi.ws...
  • Page 26 Dispose of your old equipment according to international, national, and local rules and regulations. In order to fulfil its responsibility as the product manufacturer, Physik Instrumente (PI) GmbH & Co. KG undertakes environmentally correct disposal of all old PI equipment made available on the market after 13 August 2005 without charge.

Table of Contents