The sbRIO-9607 must be installed in a suitable enclosure prior to use. Caution NI makes no product safety, electromagnetic compatibility (EMC), or CE marking compliance claims for the sbRIO-9607. The end- product supplier is responsible for conformity to any and all compliance requirements. Caution Exercise caution when designing an enclosure for the sbRIO-9607.
Connect only voltages that are below these limits. V terminal to C terminal 30 VDC maximum, Measurement Category I Preparing the Environment Ensure that the environment in which you are using the sbRIO-9607 meets the following specifications. Local ambient operating temperature near -40 °C to 85 °C...
3. Unpack any other items and documentation from the kit. Store the device in the antistatic package when the device is not in use. Verifying the Kit Contents Verify that the following items are included in the sbRIO-9607 kit. Figure 1. sbRIO-9607 Kit Contents 1. sbRIO Device 2.
NI sbRIO-9607 Specifications for system deployment. Installing Software on the Host Computer Before using the sbRIO-9607, you must install the following application software and device drivers on the host computer. 1. LabVIEW 2015 or later 2. LabVIEW Real-Time Module 2015 or later 3.
The NI sbRIO device requires a 9 VDC to 30 VDC external power supply. The NI sbRIO device filters and regulates the supplied power and provides power for RMCs. Note Refer to the Power Requirements section of the NI sbRIO-9607 Specifications for the complete power requirement specifications. Note...
Connecting the sbRIO-9607 to the Host Computer Complete the following steps to connect the sbRIO-9607 to the host computer using the RJ-45 Ethernet port. 1. Power on the host computer.
Note The default username for the sbRIO-9607 is admin. There is no default password for the sbRIO-9607, so you must leave the password field blank when logging in until you set a system password. 1. Right-click your system and select Web Configuration.
5. Click Next. 6. Select NI Scan Engine from the software add-ons. Select any additional software to install. If you plan on using the sbRIO-9607 with the LabVIEW FPGA Module, you can click Next. You can use this wizard at anytime to install additional software.
Configure the IP and other network settings by completing the following steps. 1. Use a standard Category 5 (CAT-5) or better shielded, twisted-pair Ethernet cable to connect the sbRIO-9607 Ethernet port to a host computer. The sbRIO-9607 attempts to initiate a DHCP network connection at powerup.
Table 1. STATUS LED Indicators LED Pattern Indication Blinks twice and pauses The sbRIO-9607 is in safe mode. Software is not installed, which is the factory default state, or software has been improperly installed on the sbRIO-9607. An error can occur when an attempt to upgrade the software is interrupted.
Getting Started LED Pattern Indication Blinks four times and pauses The sbRIO-9607 is in safe mode. The software has crashed twice without rebooting or cycling power between crashes. Continuously blinks The sbRIO-9607 has not booted into NI Linux Real-Time. The sbRIO-9607 either booted into...