This document describes how to begin using the NI sbRIO-9607. Safety Guidelines Operate the sbRIO-9607 only as described in the user documentation. The sbRIO-9607 must be installed in a suitable enclosure prior to use. Caution NI makes no product safety, electromagnetic compatibility (EMC), or CE Caution marking compliance claims for the sbRIO-9607.
Do not connect the sbRIO-9607 to signals or use for measurements within Caution Measurement Categories II, III, or IV. Preparing the Environment Ensure that the environment in which you are using the sbRIO-9607 meets the following specifications. Local ambient operating temperature near -40 °C to 85 °C...
Unpack any other items and documentation from the kit. Store the device in the antistatic package when the device is not in use. Verifying the Kit Contents Verify that the following items are included in the sbRIO-9607 kit. Figure 1. sbRIO-9607 Kit Contents 1. sbRIO Device 5.
Page 5
Installing Software on the Host Computer Before using the sbRIO-9607, you must install the following application software and device drivers on the host computer. LabVIEW 2015 or later LabVIEW Real-Time Module 2015 or later LabVIEW FPGA Module 2015 or later NI CompactRIO Device Drivers August 2015 or later ni.com/info...
STATUS LED Indicators section. Connecting the sbRIO-9607 to the Host Computer Complete the following steps to connect the sbRIO-9607 to the host computer using the RJ-45 Ethernet port. Power on the host computer. Connect the sbRIO-9607 to the host computer using a standard Category 5 (CAT-5) or better shielded, twisted-pair Ethernet cable.
. There is no default admin Note password for the sbRIO-9607, so you must leave the password field blank when logging in until you set a system password. Right-click your system and select Web Configuration. The NI Web-Based Configuration and Monitoring utility opens in your default browser and is where you set the password.
Page 8
Click Next. Select NI Scan Engine from the software add-ons. Select any additional software to install. If you plan on using the sbRIO-9607 with the LabVIEW FPGA Module, you can click Next. You can use this wizard at anytime to install additional software.
In MAX, expand your system under Remote Systems and select Troubleshoot Remote System Discovery. System Reset The following figure shows the reset behavior of the sbRIO-9607. Figure 3. Reset Button Behavior Press and hold RESET button for < 5 s Press and hold RESET button for ≥...
Page 10
Table 1. STATUS LED Indicators LED Pattern Indication Blinks twice and The sbRIO-9607 is in safe mode. Software is not installed, which is the pauses factory default state, or software has been improperly installed on the sbRIO-9607. An error can occur when an attempt to upgrade the software is interrupted.
Worldwide Support and Services ni.com/ The National Instruments website is your complete resource for technical support. At support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers.
Page 13
National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt ni.com/patents file on your media, or the National Instruments Patent Notice at .