Using the Default Schedule
The default schedule is designed to provide enough daily turnover to service a typical pool.
See Table 1 for default schedule.
SPEED 1
SPEED 2
SPEED 3
SPEED 1 is set to begin at 8:00am and run at 3000 RPM for a duration of 2 hours. When
SPEED 1 is complete the pump immediately begins running the default SPEED 2. SPEED 2 is
factory default to 1400 RPM and will last for 10 hours. When SPEED 2 has completed its run
the pump will run SPEED 3 at 2200 RPM for a duration of two hours.
After 14 hours of run time and completing its run of SPEED 3, the pump will enter a
stationary/paused state for the next 10 hours. The pump will restart at 8:00am the next
morning and cycle through the default schedule again. The pump will continue to run in this
in this manner until a custom schedule is programmed into the drive by the user.
Note: The Start/Stop button must be pressed, and the LED lit, for the pump to run. If the time
clock is turned off. The pump will start at speed 1 whenever the pump is powered up.
DURATION (Hours)
2
10
2
Table 1: Default Schedule
OPERATION
SPEED (RPM)
3000
1400
2200