Setting Clock - Pentair maytronics ecoclea 1500-VS Installation & Operation Manual

Table of Contents

Advertisement

OPERATION
Activating/Deactivating the Time Clock
When the pump is first plugged in, the clock will not be turned on. This means the pump will
start from speed 1, whenever the pump is powered up. The pump will then proceed to speed
2, after the programmed duration for speed 1 has elapsed and so on for speed 3. This is the
recommended setting for when the pump is connected to a salt chlorinator.
If the pump is running as a standalone device, then it is recommended to activate the time
clock.
To activate the time clock:
1. Press and hold the Display button for 3 seconds.
2. "Cloc" will be displayed on screen.
3. Use the "+" and "-" arrows to choose between time clock On or Off.
4. Press Display to advance.
5. Use the "+" and "-" arrows to adjust the screen back-light brightness.
6. Press Display to exit the Setup menu. Automatically set itself to the Speed 1 start time,
blink and advance. The pump will also run the associated schedule from that start time.
Setting the Clock
When the pump is first plugged in, the clock has not been set. Any daily schedule set by the
user will be based on this clock setting, so it will be necessary to set the clock first.
To Set the Clock:
1. Press and hold the Display button for 3 seconds.
2. Use the "+" and "-" arrows to choose between a 12 or 24 hour time format.
3. Press Display to advance in the Clock Setup menu.
4. Use the "+" and "-" arrows to change the time to the correct time of day. In the 12 hour
time format AM/ PM will display in the bottom right corner.
5. Press Display to advance.
6. Use the "+" and "-" arrows to adjust the screen backlight brightness.
7. Press Display to exit the Clock Setup menu. The clock is now set.
During a power outage, the drive will retain the clock setting in memory for as long as 24
hours. If the power is out longer than 24 hours the clock will have to be set again. If the drive
has lost the user set time, the clock will continuously blink until the time is reset. Once the
time is reset the clock will stop blinking.
Note: When power is returned to the pump after a prolonged outage (24+ hours) the clock
will automatically set itself to the Speed 1 start time, blink and advance. The pump will also
run the associated schedule from that start time.
12
1500-VS Pool Pump Owner's Manual

Advertisement

Table of Contents
loading

Table of Contents