Code 39; Code 39 Enable/Disable; Code 39 Check Character Calculation - Datalogic PowerScan PD9600 Product Reference Manual

Industrial corded and cordless handheld area imager bar code reader
Hide thumbs Also See for PowerScan PD9600:
Table of Contents

Advertisement

ENTER/EXIT PROGRAMMING MODE
The following options apply to the Code 39 symbology.

Code 39 Enable/Disable

When disabled, the reader will not read Code 39 bar codes.
$CC3EN00
Code 39 = Enable

Code 39 Check Character Calculation

Enable this option to enable/disable calculation and verification of an optional Code 39
check character. When disabled, any check character in the label is treated as a data
character.
$CC3CC00
Code 39 Check Character Calculation = Calculate Std Check
$CC3CC02
Code 39 Check Character Calculation = Enable Italian Post
$CC3CC08
132
POWERSCAN™ PD/PM96XX

CODE 39

Check
Code 39 = Disable
$CC3EN01
Code 39 Check Character Calculation = Don't Calculate
$CC3CC01
Code 39 Check Character Calculation = Calculate Mod 7
Check
$CC3CC04
Code 39 Check Character Calculation = Enable Daimler
Chrysler Check
1D SYMBOLOGIES

Advertisement

Table of Contents
loading