JOINING KIT INS TALL ATION (CONT.)
Kit Sizes: 60" (1524 mm) / 72" (1828.8 mm) / 78" (1981.2 mm) / 90" (2286 mm)
7. Install anti-sweat foam end panels on the joined
units' sides where the cabinets will meet. See figs.
13 and 14.
8. Position the units in front of the final installation
location. Then, level the units.
9. Verify the fronts of the units are flush at the seams
and the gap(s) between the units is (are) consistent
from top to bottom. See figs. 15 and 16.
10. With the provided hardware, install the joining
bracket across the interior legs. See figs. 17 and
18.
11. With the existing hardware, install the joining
rainshield assembly. See fig. 19.
NO T E: A S SI S TA NCE ( AT L E A S T T WO (2)
P EOP L E ) R EC OMMEND ED.
12. Route the reed switch wires through the rainshield.
See figs. 6 and 7.
13. With the predrilled holes in the joining rainshield,
connect and install the reed switches near the
handle-side of the units.
NO T E: BE SUR E T O C ONNEC T T HE
W IR E S T O T HE R EED SW I T CH A S
O R IGIN A L LY C ONF IGUR ED. W IR E
L O C AT ION I S CR I T IC A L T O T HE
C A BINE T ' S OP ER AT ION. SEE
F IG S. 5 O R 2 0.
TEC_TM_170 REV. B
I N S T A L L A T I O N
P A G E T I T L E
FIG. 11.
Remove and discard the interior magnet brackets.
FIG. 12.
Magnet bracket screw locations.
FIG. 13.
Install the anti-sweat foam panel where the unit will be
positioned next to another unit.
Application Area Two Pads Used
FIG. 14.
Install foam pads between the joined units.
10/18/2023
T RUE 42 /4 8 IN STA L L M A NUA L
Four Pads Used
Page 35 of 64