ANTI-TIP BR ACKE T INS TALL ATION
KIT CONTENTS
• (1) One anti-tip bracket
• (4) Four 3 ⁄16" masonry screws
• (8) Eight #12-2" wood screws
• (12) Twelve 1/4" washers
REQUIRED TOOLS
• Tape measure
• Marking utensil
• 1/8" drill bit
• 7/16" socket
• Phillips bit driver
• Drill or ratchet
WARNING! TIP OVER HAZARD.
a hazard from appliance instability,
install the anti-tip bracket.
BEFORE YOU BEGIN
Consult a flooring expert to confirm that the flooring
where the unit will be installed is rated for at least
150 lb/ft².
C L
TEC_TM_170 REV. B
TR-30REF-R-SG-A
9 9/32"
236mm
C L
FLUSH INSTALL
I N S T A L L A T I O N
PROCEDURE
1. Measure and mark the depth of the bracket's
placement in the installation location.
• Flush installation: 24-31/32" (634 mm)
• Proud installation: 22-31/32" (584 mm)
2. Place and center the bracket at the measured
depth.
3. With the bracket as a guide, drill pilot holes into
the wall and/or floor.
NOTE: FOR INCREASED STABILITY, SECURE THE
BRACKET TO AS MANY JOISTS AND/OR STUDS AS
POSSIBLE.
4. With the provided hardware, secure the anti-tip
To avoid
bracket.
5. Adjust the rear leveling rollers 1/4 turn clockwise.
6. Slide the unit into place and hook the anti-tip
bracket into the castor assembly slots.
24 31/32"
634mm
10/18/2023
T RUE 42 /4 8 IN STA L L M A NUA L
Page 29 of 64