ICEM AKER REQUIREMENT S
WAT ER SUP P LY R EQUIR EMEN T S
Units with ice-makers come with 20" (508 mm) of
polyethylene tubing with a 1/4" O.D. push connector
for customer attachment.
Before installing your unit, prepare the water supply
line. Please see plumbing requirements in the
plumbing requirements table.
• Purge the water line prior to final connection to the
unit. This removes any debris present in the line.
• Only connect to a potable water supply!
• Do not connect to a hot water supply!
• Install the water filter before turning on the
water supply to the icemaker. See "Water Filter
Installation" (page 16).
• A copper line is not recommended for this
application.
• Check all water line fittings for leaks.
• Tape the supply line to the floor before moving the
unit into its final installation location.
• In the water connection area (see the rough opening
illustration), tape the water line to the floor.
TEC_TM_170 REV. B
I N S T A L L A T I O N
P A G E T I T L E
25 25/32" 655mm
FLUSH INSTALL
23 25/32" 604mm
STANDARD INSTALL
1 1/2" 38mm
2 1/2" 64mm
10/18/2023
FIG. 1.
Water line connection. Fitting included, PEX not included
Plumbing Requirements
Water Supply
Flow Rate
ELECTRICAL LOCATED
IN THIS AREA
Operating Pressure
Incoming Water Temperature
WATER AREA
6" 152mm
TYP
41 3/4" 1060mm
PROUD INSTALL
STANDARD INSTALL
TR-42 – 41 3/4" (1060 mm)
TR-48 – 47 3/4" (1212 mm)
42 1/4" 1073mm
FLUSH INSTALL
FLUSH INSTALL
TR-42 – 42 1/4" (1047 mm)
TR-48 – 48 1/4" (1225 mm)
NOTE: DIMENSIONS MAY VARY BY ± 1/8" (3.175 mm)
T RUE 42 /4 8 IN STA L L M A NUA L
1/4" PEX tubing (1/4" O.D. lines
and fittings not included
NOTE: Copper line is not
recommended
0.5 gpm / 1.89 lpm
8" 203mm
2" 51mm
30-100 psi (207-689 kPa)
33-100°F (0.6-38°C)
84 1/4" 2140mm
FLUSH
INSTALL
84" 2134mm
STANDARD
INSTALL
77" 1956mm
Page 15 of 64