True TRCB-52 Installation Manual
Hide thumbs Also See for TRCB-52:

Advertisement

Quick Links

TRUE
manufacturing co
CONGRATULATIONS!
You have just purchased the finest commercial refrigerator
available. You can expect many years of trouble-free operation.

TABLE OF CONTENTS

WARRANTY
Warranty
TRUE MANUFACTURING CO., INC.
2001 East Terra Lane • O'Fallon, Missouri 63366-4434
(636)-240-2400 • FAX (636)-272-2408 • INT'L FAX (636)272-7546 • (800)-325-6152
Parts Department (800)-424-TRUE • Parts Department FAX# (636)-272-9471
Web: www.truemfg.com
.,
.
inc
1
2
3
4
5
6
7
8
9
13
14
15
16
trcb models
TRCB-82
INSTALLATION MANUAL
-
chef base equipment
INSTALLATION MANUAL
-
trcb
chef base equipment

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRCB-52 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for True TRCB-52

  • Page 1: Table Of Contents

    INSTALLATION MANUAL – trcb models chef base equipment TRUE MANUFACTURING CO., INC. 2001 East Terra Lane • O’Fallon, Missouri 63366-4434 (636)-240-2400 • FAX (636)-272-2408 • INT'L FAX (636)272-7546 • (800)-325-6152 Parts Department (800)-424-TRUE • Parts Department FAX# (636)-272-9471 Web: www.truemfg.com...
  • Page 2: Safety Information

    You have selected one of the finest commercial refrigeration units made. It is manufactured under strict quality controls with only the best quality materials available. Your TRUE cooler when properly maintained will give you many years of trouble-free service. WARNING: Use this appliance for its intended purpose as described in this Owner Manual.
  • Page 3: Proper Disposal, Connecting Electricity, & Adapter Plugs

    NEMA plugs TRUE uses these types of plugs. If you do not have the right outlet have a certified electrician install the correct power source. NOTE: International plug configurations vary by voltage and country.
  • Page 4: Installation

    The cost of a professional installation is money well spent. • Appliance tested according to the climate classes 5 and 7 Before you start to install your TRUE unit, carefully inspect it for temperature and relative humidity. freight damage. If damage is discovered, immediately file a claim with the delivery freight carrier.
  • Page 5: Wire Gauge Chart

    TRUE – trcb chef base equipment truemfg WIRE GAUGE CHART 115 Volt s Distance In Feet To Center of Load 230 Volts Distance In Feet To Center of Load Amps 20 30 40 50 60 70 80 90 100 120 140 160...
  • Page 6: Locating And Leveling

    PLUGGING INTO POWER SOURCE. INSUFFICIENT. Remove skid by unscrewing all base rail anchor brackets. Place Proper leveling of your TRUE cooler is critical to operating skid to the side. success (for non-mobile models). Effective condensate removal and door operation will be effected by leveling.
  • Page 7: Installation Of Legs Or Castors

    TRUE – trcb chef base equipment truemfg INSTALLATION OF CASTORS OR OPTIONAL LEGS Important safeguard for installation of leg/castor. Images 1 & 2 demonstrate procedure. LEVELING CASTORS Four sets of shims have been provided in warranty packet for leveling castored units positioned on uneven floors. Shims must be positioned...
  • Page 8: Setup

    TRUE – trcb chef base equipment truemfg SETUP STANDARD ACCESSORIES DRAWER REMOVAL & INSTALLATION Depending on the version and model of the cabinet, one of the fol- lowing drawer configurations will be standard. DRAWER SET 2 DRAWER SET 1 REMOVAL REMOVAL Slide out drawer and locate white drawer retainer.
  • Page 9: Operation

    RECOMMENDATION - Before loading product we recommend • Mechanical temperature control is located inside of unit. you run your TRUE unit empty for two to three days. This allows you See website for adjustments, sequence of operation, and more to be sure electrical wiring and installation are correct and no ship- information.
  • Page 10: Mechanical Temperature Controls Sequence Of Operation

    TRUE – trcb chef base equipment truemfg MECHANICAL TEMPERATURE CONTROLS COIL SENSING An evaporator coil sensing temperature control ensures that the evaporator coil will remain clear of frost and ice by not allowing the compressor to restart until the coil temperature is above the freezing temperature.
  • Page 11 TRUE – trcb chef base equipment truemfg WHEN TO MAKE AN ADJUSTMENT TO A MECHANICAL TEMPERATURE CONTROL We advise to make a mechanical temperature control adjustment only for a high altitude location. HOW TO ADJUST A MECHANICAL TEMPERATURE CONTROL OPERATION INSTRUCTIONS:...
  • Page 12 TRUE – trcb chef base equipment truemfg INSTRUCTIONS: DANFOSS TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE APPLICATIONS STEP 1 - Unplug cooler. STEP 2 - Remove the screws that secure the temperature control to the inset box. STEP 3 - To make these adjustments it may be necessary to remove the temperature control from the housing.
  • Page 13 TRUE – trcb chef base equipment truemfg CHART CCW Adjustment (based on 360°/ Height complete turn) 2000' 42° 3000' 78° 4000' 114° 5000' 150° 6000' 186° 7000' 222° 8000' 258° 9000' 294° 10,000' 330° BUL. NO.
  • Page 14: Maintenance, Care, Cleaning

    TRUE – trcb chef base equipment truemfg MAINTENANCE, CARE, CLEANING CLEANING THE CONDENSER COIL When using electrical appliances, basic safety precautions should be followed, including the following: TOOLS REQUIRED 35ϒ Fϒ • Phillips Screwdriver • Air Tank or CO2 Tank •...
  • Page 15: Important Warranty Information

    Reconnect the electrical power to the unit. rear of the unit. You must remove the cabinet grill to expose the If you have any questions, please call TRUE Manufacturing at 636- Condenser. 240-2400 or 800-325-6152 and ask for the Service Department.
  • Page 16: Stainless Steel Equipment Care And Cleaning

    TRUE – trcb chef base equipment truemfg STAINLESS STEEL EQUIPMENT CARE 8 STEPS THAT CAN HELP PREVENT RUST ON AND CLEANING STAINLESS STEEL: CAUTION: Do not use any steel wool, abrasive or chlorine based USING THE CORRECT CLEANING TOOLS products to clean stainless steel surfaces.
  • Page 17 TRUE and upon proper installation and start-up in accordance with the instruction packet supplied with each TRUE unit. TRUE’s obligation under this warranty is limited to a period of three (3) years from the date of original installation or 39 months after shipment date from TRUE, whichever occurs first.