Advertisement

Quick Links

Translation of the Original Operating Instructions EN
Controller IRG1- MS (230 V/50 Hz)
Controller IRG1- MS (115 V/60 Hz)
Operating instructions EN
Operating Instructions
Controller
IRG1-MS
Order no: 50391018
Order no: 50391018
IRG1- MS
11.02.2024
Version 3.0
1-24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 50391018 and is the answer not in the manual?

Questions and answers

Summary of Contents for Afag 50391018

  • Page 1 Operating Instructions Controller IRG1-MS Translation of the Original Operating Instructions EN  Controller IRG1- MS (230 V/50 Hz) Order no: 50391018 ◼  Controller IRG1- MS (115 V/60 Hz) Order no: 50391018 ◼ Operating instructions EN ◼ IRG1- MS ◼...
  • Page 2 Your Afag team © Subject to modifications The controllers have been designed by Afag GmbH according to the state of the art. Due to the constant technical development and improvement of our products, we reserve the right to make technical changes at any time.
  • Page 3: Table Of Contents

    Table of contents Table of contents General ........................5 Contents and purpose of this manual ............5 Explanation of symbols................. 5 Additional symbols ..................6 Warranty ....................... 7 Liability ......................7 Safety instructions ....................8 General ......................8 Intended use ....................8 Foreseeable misuse ..................
  • Page 4 Table of contents Settings ....................... 19 Maintenance ......................20 Safety instructions ..................20 Maintenance activities and maintenance intervals ........21 8.2.1 Maintenance point ................21 8.2.2 Replacing the fuse................21 Spare and wear parts, repairs ..............21 Decommissioning and disposal ................. 22 Safety instructions ..................
  • Page 5: General

    General General Contents and purpose of this manual These assembly instructions contain essential information on assembly, commissioning, functioning and maintenance of the controller IRG1-MS to ensure safe and efficient handling and operation. Consistent compliance with these operating instructions will ensure: ▪...
  • Page 6: Additional Symbols

    General This note contains important additional information as well as useful tips for safe, efficient, and trouble-free operation of the controllers. Further warning signs: Where applicable, the following standardised symbols are used in this manual to point out the various potential health risks. Warning - Dangerous electrical voltage.
  • Page 7: Warranty

    General Warranty The warranty terms for Afag feeding components and handling systems are the following: ▪ 24 months from initial operation and up to a maximum of 27 months from delivery. ▪ Wear parts are excluded from the warranty (The customer is entitled to a product free of defects.
  • Page 8: Safety Instructions

    Safety instructions Safety instructions General This chapter provides an overview of all important safety aspects to ensure safe and proper use of the controllers and optimal protection of personnel. Safe handling and trouble-free operation of the controller requires knowledge of the basic safety regulations.
  • Page 9: Obligations Of The Operator And The Personnel

    Safety instructions Obligations of the operator and the personnel 2.4.1 Follow these instructions A basic prerequisite for safe and proper handling of the controllers is a good knowledge of the basic safety instructions. This manual, particularly the safety instructions contained therein, must be observed by all persons working with the controllers.
  • Page 10: Personnel Requirements

    Safety instructions Personnel requirements 2.5.1 Personnel qualification The activities described in the operating instructions require specific requisites at the level of professional qualifications of the personnel. Personnel not having the required qualification will not be able to assess the risks that may arise from the use of the controllers thus exposing himself and others to the risk of severe injury.
  • Page 11: Changes And Modifications

    No changes may be made to the controller which have not been described in these operating instructions or approved in writing by Afag. Afag accepts no liability for unauthorised changes or improper assembly, installation, commissioning, maintenance, or repair work. General hazards / residual risks Observe the safety instructions in this chapter and in the other sections of this manual to avoid damage to property and dangerous situations for the personnel.
  • Page 12: Technical Data

    Technical data Technical data Dimensional drawing controller IRG1-MS Fig. 1 Dimensional drawing of IRG1-MS controller 12 - 24 Operating instructions EN ◼ IRG1- MS ◼ 11.02.2024 ◼ Version 3.0...
  • Page 13: 3.2 Technical Data Controller Irg1-Ms

    Technical data 3.2 Technical data controller IRG1-MS Accessories Type Designation Order Number for 1 IRG 50450178 for 2 IRG 50450179 Support for 1 IRG extended 50450145 for 2 IRG extended 50450147 Operating instructions EN ◼ IRG1- MS ◼ 11.02.2024 ◼ Version 3.0 13-24...
  • Page 14: Transport And Storage

    Transport and storage Transport and storage Scope of supply The corresponding documentation is supplied with each controller. Fig. 2 Scope of delivery IRG1-MS [Unt] Designation Controller Operating Instructions 14 - 24 Operating instructions EN ◼ IRG1- MS ◼ 11.02.2024 ◼ Version 3.0...
  • Page 15: Transport

    Transport and storage Transport No liability can be assumed for damages caused by improper installation on the part of the operating company. The following conditions must be complied with for transport and storage: ▪ Storage temperature: 0-+45 °C ▪ Relative air humidity: < 90%, non condensing Storage If the controller is stored for an extended period, observe the following: ▪...
  • Page 16: Design And Function

    Design and function Design and function Design of the controller Output active message On-/Off switch Connection Fig. 3 Design of the IRG1-MS controller Functional description The IRG1-MS is a controller for 1-phase capacitor motors. Via an enable input (M8), the module can be switched on or off by a higher-level system, e.g.
  • Page 17: Mounting And Installation

    Mounting and installation Mounting and installation For safe operation, the module must be integrated into the safety concept of the system in which it is installed. The system operator is responsible for the installation of the controller in a system! Safety instructions WARNING Danger! Risk of electric shock!
  • Page 18: Mounting/Fastening The Controller

    Mounting and installation Mounting/fastening the controller Two holes are provided on the lower part of the housing for mounting the controller. These are separated from the interior of the housing. (Fastening dimension: 163 x 52 mm). NOTICE Damage to the circuit board! Incorrect adjustment of the slide switches can cause a malfunction or damage the circuit board! ▪...
  • Page 19: Operation And Settings

    Operation and settings Operation and settings Safety instructions DANGER Risk of injury due to electric shock! Unauthorized removal of the plug cover causes a risk of electric shock! ▪ Do NOT dismount the plug cover! ▪ Avoid any action on the module which could endanger safety! NOTICE Damage of the controller! If the controller plug is plugged in or unplugged from the vibratory drive when...
  • Page 20: Maintenance

    Maintenance Maintenance Safety instructions DANGER Risk of injury due to electric shock! Work on the electrical system carried out unprofessionally can cause serious or fatal injuries. ▪ Work on the machine's electrical equipment may only be performed by skilled electrician or trained personnel under the supervision of a skilled electrician in accordance with all relevant electrical regulations.
  • Page 21: Maintenance Activities And Maintenance Intervals

    The process is complete.  Spare and wear parts, repairs Afag offers a reliable repair service. Defective devices can be sent to Afag for warranty repair within the warranty period. Repair work may only be carried out by qualified personnel! We recommend that you have the repair carried out at our premises.
  • Page 22: Decommissioning And Disposal

    Decommissioning and disposal Decommissioning and disposal The controller must be properly dismounted after use and disposed of in an environmentally friendly manner. Safety instructions WARNING Risk of injury due to improper decommissioning and disposal! Improperly carried out activities can result in considerable material damage and severe injury.
  • Page 23 Operating instructions EN ◼ IRG1- MS ◼ 11.02.2024 ◼ Version 3.0 23-24...
  • Page 24 24 - 24 Operating instructions EN ◼ IRG1- MS ◼ 11.02.2024 ◼ Version 3.0...

This manual is also suitable for:

Irg1-ms