Page 1
Controller PSG 1 Translation of original operating instruction Copyright by Afag GmbH...
Page 2
This operation instruction applies to: Type Order number Controller PSG 1 230 V, 50/60 Hz 50211833 Version of documentation: BA_PSG1_R1-1_E Release: Datum: 2011-08-06 Release: 1.1 2011-08-06 Page 1...
Table of contents: Declaration of conformity ................. 3 Safety instructions .................... 4 Notes on symbols and instructions ......................4 Basic safety information ........................5 Appropriate use ............................. 5 Description of the device .................. 6 General ..............................6 Technical data ............................7 Assembly instructions ..................
1 Declaration of conformity The manufacturer: Afag GmbH, Wernher-von-Braun-Strasse 5a, D-92224 Amberg www.afag.com – Tel. +49 (0)9621 650 27-0 hereby declares, that the product: Controller Designation: PSG1 complies with the basic safety and health requirements of the EMC-Directive 2004/108/EC. The product also complies with the following applied, harmonised standards:...
2 Safety instructions 2.1 Notes on symbols and instructions Symbols: Assembly and commissioning must be carried out by qualified per- sonnel only and according to these operating instructions. Please observe the meaning of the following symbols and notes. They are grouped into risk levels and classified according to ISO 3864-2.
2.2 Basic safety information This description contains the necessary information for the correct application of the product described below. It is intended for use by technically qualified personnel. Qualified personnel are persons who, because of their training, experience and posi- tion, as well as their knowledge of appropriate standards, regulations, health and safety requirements and working conditions, are authorised to be responsible for the safety of the equipment, at all times, whilst carrying out their normal duties and are...
3 Description of the device 3.1 General The PSG1 is a frequency converter for the operation of oscillating conveyors with Pi- ezo drive. It generates an adjustable drive frequency which is independent of the mains frequency. The output voltage is adapted to the Piezo unit so that voltages be- tween -30 and 150 V are generated.
3.2 Technical data Figure 1: PSG1 Table 1: Technical data Type Units PSG1 Supply voltage [VAC] 230 V / ±10% Supply frequency [Hz] 50 / 60 Output voltage [VAC] -30 ÷ +150 Output current [mA] pp / 100 Output frequency 5 ÷...
4 Assembly instructions 4.1 Installing the unit 3 oblong holes are provided at the backside for attachment. The device can be oper- ated either in a vertical or in a horizontal position. 4.2 Installation NOTE Do supply voltage, operating voltage of the conveyor and control- ler input voltage match? Is the controller adequately rated for the rated power of the feed- What is the vibrating frequency of the feeder?
5 Operating instructions 5.1 Menu operation Menus are used for changing settings. The different parameters are selected by en- tering a code. All adjustments are made by first pressing the P key, followed by selecting the menu code, using the cursor keys. Settings: Pressing the cursor key for a short time causes one digit increase/decrease, holding down for a longer time gives changes in ten-digit steps.
5.2 Settings Table 2: Settings The specific settings for a system can be saved by selecting “PUSH” in menu C 000 (recall settings via menu C 000 “US.PA”) NOTE Error messages must be cleared in menu no. C 009 by means of “Cl.err.”.
6 Maintenance instructions 6.1 Troubleshooting and fault repair Fault: Fault repair Appliance not working Check the mains voltage, check the fuses and replace if necessary. Check the control signals and reset to factory settings, if necessary (see chapter 5.2 Set- tings) Conveyor not working Check the mains frequency (50/60 Hz).
Need help?
Do you have a question about the PSG 1 and is the answer not in the manual?
Questions and answers