Graco 24J415 Instructions-Parts List Manual page 19

Communications gateway module installation kit
Hide thumbs Also See for 24J415:
Table of Contents

Advertisement

Units
Change
Depending on system
Dispense
setup the units can be
Flow Rate
by weight, volume,
or Pres-
flow, or pressure
sure Set
point
Change
Depending on system
Dispense
setup the units can be
Amount
by weight, volume, or
Set point
time
Change
Depending on system
material
setup the units can be
Ratio Set
by weight or volume
point
Change
Select conditioning
Tempera-
zone set point to
change
ture Con-
ditioning
MSW = Conditioning
Set point
Zone Selected
LSW = Temperature
setpoint in 0.1 degree
increments
(example: 501 = 50.1)
3A1704H
CGM Input
In
from PLC
Byte
Output
Byte
13-16 Integer value of
the requested
rate in the dis-
pensing sys-
tem.
17-20 Integer value of
the requested
Dispense
amount in the
dispensing sys-
tem.
21-22 Integer value of
the requested
Material Ratio
in the dispens-
ing system.
Blue: Red
23-24 0 = Red Tank
1 = Blue Tank
2 = Red Inline
3 = Blue Inline
4 = Red Hose
5 = Blue Hose
6 = Red Chiller
7 = Blue Chiller
Out
CGM Output
to PLC Input
--
--
Changes current shot selected to a
new rate. The value outputted to the
CGM must be an integer. The PLC
value is xxx.xxx and must be multi-
plied by 1000 prior to being sent to
the CGM
--
--
Changes current shot selected to a
new dispense amount. The value
outputted to the CGM must be an
integer. The PLC value is xxx.xxx
and must be multiplied by 1000 prior
to being sent to the CGM
--
--
Changes current shot selected in a
variable ratio system to a new ratio.
The value outputted to the CGM
must be an integer and must be
multiplied by 100 for the requested
material Ratio. Blue is the value
and Red is always = 1.
is: Blue: Red == xx.xx:1
--
--
When changing a heat zone, select
the appropriate zone number which
will enable the CGM to write a new
temperature set point to the heat
zone selected. Only 1 heat zone
can be selected at a time.
MSW + LSW combined to form a
DINT from the PLC output to CGM
input.
NOTE: If the system is a standard
HFR, the LSW setpoint must be
0.1 °C, regardless if Fahrenheit
mode is selected on the ADM.
Available Internal Data
Descriptions
PLC input
19