Graco 24J415 Instructions-Parts List Manual page 15

Communications gateway module installation kit
Hide thumbs Also See for 24J415:
Table of Contents

Advertisement

Units
Ratio of
Depending on system
the Blue /
setup the units can be
Red mate-
by weight or volume
rial - set-
point
Pump Red
PSI, bar, or MPa
Pressure -
Actual
Pump
PSI, bar, or MPa
Blue Pres-
sure -
Actual
Pump
Depending on system
Flow -
setup the units can be
Actual
by weight or volume
Ratio of
Depending on system
the Blue /
setup the units can be
Red mate-
by weight or volume
rials
-Actual
Dispense
Depending on system
Amount -
setup the units can be
Actual
by weight or volume
Dispense
mS
Duration
-Actual
Blue Inline
Depending on system
Temp -
setup the units can be
Actual
read in C or F
Blue Hose
Depending on system
Temp -
setup the units can be
Actual
read in C or F
Red Inline
Depending on system
Temp -
setup the units can be
Actual
read in C or F
3A1704H
CGM Input
In
from PLC
Out
Byte
Output
Byte
--
--
23-24 Integer value
--
--
25-28 Integer value
--
--
29-32 Integer value
--
--
33-36 Integer value
--
--
37-38 Integer value
--
--
39-42 Integer value
--
--
43-46 Actual Dura-
--
--
47-48 Actual tem-
--
--
49-50 Actual tem-
--
--
51-52 Actual tem-
CGM Output
to PLC Input
Monitoring Only. The value from the
of the Blue /
CGM is an integer and must be mul-
Red Material
tiplied by 0.01 for the requested
Ratio setpoint
material Ratio to be in system units
in the dis-
Blue is the value and Red is always
pensing sys-
= 1. Blue: Red == xx.xx:1
tem.
Monitoring Only. The value from the
of the actual
CGM is an integer and must be mul-
Red pump
tiplied by 0.0001 for the actual Red
pressure in
pump pressure to be in system units
the dispens-
ing system.
Monitoring Only. The value from the
of the actual
CGM is an integer and must be mul-
Blue pump
tiplied by 0.0001 for the actual Blue
pressure in
pump pressure to be in system units
the dispens-
ing system.
Monitoring Only. The value from the
of the actual
CGM is an integer and must be mul-
Flow rate in
tiplied by 0.0001 for the actual flow
the dispens-
rate to be in system units
ing system.
Monitoring Only. The value from the
of the actual
CGM is an integer and must be mul-
Material Ratio
tiplied by 0.01 for the Actual material
in the dis-
Ratio to be in system units. Blue is
pensing sys-
the value and Red is always = 1.
tem.
Blue: Red == xx.xx:1
Monitoring Only. The value from the
of the actual
CGM is an integer and must be mul-
Dispense
tiplied by 0.001 for the actual
amount in the
amount to be in system units
dispensing
system.
Monitoring Only. Time base is 0.001
tion of the dis-
seconds == xxx ms.
pense in mS
Monitoring Only. The value from the
perature
CGM is an integer and must be mul-
tiplied by 0.1 for the actual tempera-
ture to be in system units.
perature
perature
Available Internal Data
Descriptions
15