14 | CGM Control
Enabled
15 | USED INTER-
NALY
Operating
System Mode Select
Mode
Selected
Select Shot number,
Shot
or Sequence Position
Number
Selected
Select sequence
Sequence
Condition-
ing / Heat
zones
3A1704H
CGM Input
In
from PLC
Out
Byte
Output
Byte
0 = ADM has
control of the
system
1 = CGM has
control on the
system
--
3
DISABLED
Mode = 1
STANDBY
Mode = 2
SHOT Mode=
3
SEQUENCE
Mode = 4
OPERATOR
Mode = 5
PRIME Mode =
6
NIGHT Mode=
7
4
In Shot Mode,
Selects the
Active Shot
number. In
Sequence
Mode, selects
the Active
Sequence
position num-
ber.
5
In Sequence
mode, selects
that active
sequence. Is
ignored in
other modes
6
Bit 0 = 1, Red
Tank heat
enable
CGM Output
to PLC Input
0 = CGM can
Select via the PLC the control of the
only monitor
system from either the CGM or the
ADM. CGM can monitor status in
1 = CGM can
either mode.
control the
system
--
3
DISABLED
PLC selects the various modes of
Mode = 1
the dispensing system.
STANDBY
CGM feedbacks the status of the
Mode = 2
system to the PLC.
SHOT Mode=
3
Prime mode is only available for
SEQUENCE
variable ratio systems.
Mode = 4
OPERATOR
Night mode is only available on
Mode = 5
standard HFRs with full circulation
PRIME Mode
systems.
= 6
If using a manually controlled dis-
NIGHT
pense valve, shot and sequence
Mode= 7
modes are not available.
4
Shot or
Select, via the PLC, the active shot
Sequence
number when in Shot mode or the
number feed-
Current Sequence position number
back
when in Sequence mode
5
Sequence
Select via the PLC the active
selected feed-
sequence when in Sequence mode
back
6
Bit 0 = 1, Red
PLC enables / disable the various
Tank heat ON
Conditioning Zones.
Setting the bit = 1 enables the Heat
Zone.
Setting the bit = 0 disables the Heat
Zone.
Feedback: 0 = zone OFF, 1 = Zone
ON
Available Internal Data
Descriptions