2. Release and remove the four spacer screws.
3. Install the four spacer screws with the desired
height. The max. tightening torque is 1.5 Nm.
4. Insert the support grid (1) and secure using
the four size-M5 screws. The max. tightening
torque is 1.5 Nm.
5. Connect the product to the supply lines.
6. Before starting the handling process, check to
ensure proper installation and function.
10.6   Variant X only: Cleaning or Replacing the Ejector Module
10.6.1   Removing the Ejector Module
ü The device has been disconnected from all supply lines.
1. Release the fastening screws for the silencer
cap.
EN-US · 30.30.01.04063 · 00 · 02/24
10 Maintenance and Cleaning