Page 1
The complete description of the device can be found in the detailed operating in- structions at www.schmalz.com or is available on request. These brief operating instructions make no claim to being exhaustive. Store in a safe place for future reference. Subject to technical changes without notice. No re- sponsibility is taken for printing or other types of errors.
Page 2
1 Product Description 1.1 Operating Modes If the ejector is connected to the supply voltage, it is ready for operation. This is the normal operating mode, in which the ejector is operated by the system controller. The ejector is parameterized via the available menus or via IO-Link. The following operating modes are available during the setup process: •...
Page 3
Supply voltage DC 24 V ± 10% (PELV Polarity reversal protection Current consumption — Typical current consumption Max. current consumption (at 24 V) SCPMi – xx – NC 50 mA 70 mA SCPMi – xx – NO 75 mA 115 mA NFC Forum Tag type 4 IO-Link IO-Link 1.1 Baud rate COM2 (38.4 Kbits/s)
Page 4
1. Compare the entire delivery with the supplied delivery notes to make sure nothing is missing. 2. Damage caused by defective packaging or occurring in transit must be reported immediately to the carrier and J. Schmalz GmbH. 4 / 7 EN-US · 30.30.01.02095 · 01 · 09/21...
Page 5
6 Installation Instructions CAUTION Improper installation or maintenance Personal injury or damage to property 4 During installation and maintenance, make sure that the product is disconnected and depressur- ized and that it cannot be switched on again without authorization. For safe installation, the following instructions must be observed: •...
Page 6
OUT / CQ Black “Parts control” output (SP2) or IO- Link Gray “Blow-off” signal input — Pink Not used When using a Schmalz connection cable, part no. 21.04.05.00488 (see accessories) 6 / 7 EN-US · 30.30.01.02095 · 01 · 09/21...
Page 7
9 General Preparations WARNING Extraction of hazardous media, liquids or bulk material Personal injury or damage to property! 4 Do not extract harmful media such as dust, oil mists, vapors, aerosols etc. 4 Do not extract aggressive gases or media such as acids, acid fumes, bases, biocides, disinfectants or detergents.
Need help?
Do you have a question about the SCPMi and is the answer not in the manual?
Questions and answers