Diagnosis in the case of failure

The device LEDs signal the following error states:
LED
Red
flashing
(6 Hz)
Red
flashing
(6 Hz)
Red
flashing
(6 Hz)
Red
flashing
(3 Hz)
Leuze electronic
LED
LED
Yellow
flashing
(6 Hz)
Red
Red
flashing
(6 Hz)
Yellow,
Red,
flashing
flashing
fast
fast
Red
Diagnosis in the case of failure
Meaning
Double sheet moni-
toring not calibrated
No single sheet
No sheet inserted or
detected during cali-
double sheet
bration
inserted
Amplifier detects an
excessively high
Extreme interfering
noise level when
noise
switching on
Current at output too
Short-circuit
high
Fatal memory error
Defective
DB 112 B
Cause
Remedy
Perform calibration
Calibrate on single
sheet
Quiet the interfering
noise, e.g., with
foam
Switch off voltage,
check wiring
Have repaired by
Leuze electronic