Appendix:
Model of truck:
Model of battery:
Fluid level of
Date
electrolyte
(Normal / lower)
Density of electrolyte (St):
S25=St+0.0007(t-25)
S25: The density when the temperature is 25℃
St: The density when the temperature is t℃ (measured value)
t: The temperature of liquid (measured value)
Final voltage: about 52V(1-2.5t)
Charged electricity: 130%-150% of battery ration.
Liquid level: Higher than the shield for 15-20mm
Abnormal condition:
Note:
Please copy and fill in this list strictly, it will provide basis for maintenance and
service of battery.
Charging record card of electric forklift truck
Identification No:
Battery No:
Density of
electrolyte (g/cm
(before charge
/after charge)
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
It must be charged when the density of electrolyte is lower than 1.160g/cm
about 86.8V(3t)
Charging
3
)
Voltage
hours
(Begin/End)
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
78
Date of purchasing:
Date of first using:
Charged
electricity
(V)
(Ah)
Distilled
water (ml)
3
.