4.2 SME compact meter

4.2.1 General description
Three-wheel AC electric forklift truck adopts Italy SME newly LCD meter, displaying in
real-time on high definition LCD. The CAN wire of meter is connected with control main
board according to RS232 communication standard. The EYE software obtains allowable
landing and upgrade panel, with functions of detailed upgrade, diagnosis and adjustment.
The control circuit adopts SCM technology, sampling, displaying and controlling in
real-time. The intense and feeble circuit in the instrument adopts light-electricity separating
with control relay.
4.2.2 Outline and instructions of meter
Traveling speed (km/h)
Hand brake switch, lamp lights when pulling the hand brake
With safety seat switch open, meter indicates seat symbol, main
contactor can't be connected and truck can't travel until seat switch
closes.
Time meter (Odometer)
Turning angle, indicating the position of rear wheel
Maintenance time indication
Remind the users to maintain and service the forklift truck.
Slow-speed operating
With the lamp on, the traveling speed and lifting speed will be
reduced in slow-speed mode.
37