Page 2
1 year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling.
Table of Contents Title Page Introduction..........................................Safety Information ........................................Contact Fluke ........................................... Accessories ..........................................Specifications........................................... Before You Start ........................................Unpack and Inspect ...................................... Storage ..........................................Battery ..........................................Display............................................Controls and Connections ....................................Power On/Off ..........................................Auto Power Off......................................... How to Operate........................................
Page 4
802EN Users Manual Backlight........................................Flashlight........................................Accessory Connectors ....................................10 External Sensor ..................................... 10 Audio ......................................... 12 ISO 10816 Standards....................................13 ISO 10816-1 ......................................13 Important Terms ....................................14 General Maintenance ......................................14 Care..........................................14 How to Clean ......................................14 Battery Replacement................................... 15...
Introduction Contact Fluke The 802EN Vibration Meter (the Product) is a screening tool Fluke Corporation operates worldwide. For local contact for overall vibration measurements on machines. The information, go to our website: www.fluke.com. Product includes these features: To register your product, or to view, print, or download the •...
802EN Users Manual Accessories Velocity Range .......... 0.1 mm/s to 199.9 mm/s rms Table 1 is a list of the accessories available for the Product. Resolution........0.1 mm/s Accuracy ........±(5 % +2 digits) (10 Hz to 1 kHz) Table 1. Accessories...
Page 7
Vibration Meter Specifications Amplitude Units Vibration Limit ......500.0 m/s² peak Electromagnetic Compatibility Acceleration........g, m/s International........IEC 61326-1: Portable Velocity........... mm/s Electromagnetic Environment Displacement ....... mm CISPR 11 ........Group 1, Class A Battery Type........2 AAA, IEC LR03 Group 1: Equipment has intentionally generated and/or uses External Piezoelectric Accelerometer conductively-coupled radio frequency energy that is...
802EN Users Manual Before You Start Display This section helps you to know the Product parts, controls, Table 2 shows the typical elements on the Product display. and connections. Unpack and Inspect Carefully unpack and inspect the: • Vibration Meter •...
Vibration Meter Controls and Connections Controls and Connections Table 2. Typical Elements on the Product Display Table 3 shows the location of the controls and connections for the Product. Item Description Battery status Save reading Hold reading Measurement units LF/HF switch External sensor Record storage...
Page 10
802EN Users Manual Table 3. Product Controls and Connections Item Control Power on/off Measure Save/mode switch/unit switch Bottom cap View records Backlight on/off and flashlight on/off Flashlight Piezoelectric Accelerometer Audio port External sensor port...
Vibration Meter Power On/Off Power On/Off • Push to view existing reading or clear all stored data. Push and hold O for over one second to turn on/off the Measurement Modes Product. See Table 3 for the control location. The units of measure are adjustable for different standards.
802EN Users Manual Figure 1. Correct and Incorrect Measurement Angles After startup, the Product is in standby mode. The main screen shows “----“ and the last set measurement unit. 1. Push and hold to enter measurement mode and view measurement reading.
Vibration Meter How to Operate A maximum of 99 measurement readings can be stored in Note the memory. When the memory is full, the Product The backlight automatically turns off after automatically deletes the earliest reading. 120 seconds of inactivity. View Memory Flashlight When the Product is on:...
802EN Users Manual Accessory Connectors Figure 3. External Accelerometer The Product has two accessory connectors: • External Sensor • Audio External Sensor In addition to the built-in piezoelectric accelerometer, an optional external sensor connects to the Product. The connector type for the external sensor is a Subminiature version B (SMB).
Page 15
Vibration Meter How to Operate To set the sensitivity for the external sensor: 1. Turn on the Product while pushing at the same time. The screen shows the model number and software version number. Note You must set the sensitivity in mV/m/s² units. 3.
802EN Users Manual Audio Figure 4. Audio Connection The Product has an audio connector for headphones. Headphones are useful to detect unusual machine sounds. To listen to a machine: 1. Open the bottom cap of the Product and connect the audio connector.
Vibration Meter How to Operate ISO 10816 Standards Table 4. Vibration Severity - ISO 10816-1 As an alternative to the Overall Vibration Severity Scale Machine Class I Class II Class III Class IV included in the Product, you can use the ISO Standard Small Medium Large Rigid...
802EN Users Manual Important Terms W Caution Class I: Individual parts of engines and machines integrally To prevent damage to the Product or any connected to the machine in normal operation. Production performance loss, do not put the Product in electrical motors at a maximum of 15 kW are examples of temperature extremes.
Vibration Meter General Maintenance Battery Replacement Figure 5. Battery Replacement The Product operates on two AAA batteries. To replace the batteries: 1. Turn the Product over and loosen the battery cover screw. 2. Remove the battery cover from the Product, see Figure 3.
2. Make sure the batteries are properly aligned and secured. The Product does not turn on. The battery connection is loose. 3. If the problem continues, contact the Fluke Service Center for technical support. 1. Restart the Product. Buttons do not operate.