2. Hardware Functionality
2.8 Serial Interfaces
The RS232, RS485 CAN serial interfaces together with the two I/O interfaces are physically connected
to the 14-pin terminal block panel socket. All these interfaces are not isolated from the router. The pinout
of this connector is described in Figure
ICR-4401 Hardware Manual
16
and the tables below.
Figure 16: Serial Connector Pinout
Pin
Signal mark
1
RXD
2
CTS
3
GND
4
RTS
5
TXD
Table 11: Connection of RS232
Pin
Signal mark
6
CAN_H
7
CAN_L
Table 12: Connection of CAN Bus
Pin
Signal mark
8
B (+)
9
A (-)
10
GND
Table 13: Connection of RS485
Description
Received Data
Clear to Send
Ground
Request to Send
Transmit Data
Description
CAN High
CAN Low
Description
In/Out
In/Out
Ground
2.8 Serial Interfaces
20