IBM 2025 Maintenance Manual page 222

Processing unit
Table of Contents

Advertisement

5 .• 10 SERVICE CHECKS AND CHECKOUT PROCEDURES
(FIG.URE 5-2)
Continued problems with the 2025 power
supplies could be an indication that:
1.
Line in use is out of specification.
The voltage must be within ±103 of
rated input line voltage..
(See
Physical Planning Manual, Form
C22-6820,, for complete requirements .. )
2..
Transformer taps set for wrong line
voltage..
If the voltage is ever
changed, the correct Feature Bill of
Material should be ordered through
Plant Field Engineering.
These
B/~s
contain complete instructions for the
2025 conversion as well as the correct
voltage nameplate tags.
The voltage
nameplate must always reflect the
voltage for which the machine is wired.
When the B/M is ordered and installed,
Machine Level Control Department is
advised of the change in the machine
voltage wiring.
3.
On thermal failures, check blowers and
filters for sufficient air flow.
Room
temperature can also be a factor.
Logic Page
Descripton
Part Number
EC133201
EC133323
EC133539
YA011
Switching Instruction for Input Voltage
2542161
YA021
Machine Layout Data (Door Side)
2542162
2543021
2470741
YA022
Machine Layout Data (Gate Side)
2542163
2470739
YA031
Power "On" - "Off" Se_g_uence
2542164
YA041
Component Data Location Chart
2542165
2543022
YA042
Component Data Location Chart
2542166
2470747
YA043
Terminal Location Chart
2542167
YA061
Connector Reference Chart
2542168
YA071
External Cable Connections
2542169
2470740
YA072
External Cable Connections
2542170
YA091
AC Power Control
2542171
2543023
YA092
Control Transformer and Conv. Outlet Power Dist.
2542172
YA101
AC Distribution
2542173
YA111
AC - Distribution to 1052 and Blower Circuits
2542174
YA131
1403 AC - Control and Distribution
2542175
2470732
YA132
Solid State Switch and 1403 Motors
2542191
YA141
1403 +60 V Control and Disteibution
2542176
2470733
YA151
System Power Control
2542177
YA161
System Power Control
2542178
YA171
EPO and PWR "On" Control for
1/0
Control Units
2542179
YA181
Voltage Sense Circuits CB Trip Sense Circuits, Over
2542180
Temperature Circuits
YA185
Lall'lQ_Su.QQ!y_and Time Meter Circuit
2542181
YA191
Ferro Mid Pack Tl T2, and Power Supplies PSl, PS4 2542182
YA201
Ferro Mid Pack T6, T7, and Power Supplies PS2, PS5, 2542183
PS11, PS12
YA211
-3 V - Power Su.£.e!y_ and Distribution
2542184
YA221
+3V - Power Supply and Distribution
2542185
YA231
+6 V - Power Supply and Distribution
2542186
YA241
+12V, -12V- Power Supply and Distribution
2542187
YA251
DC Distribution to Gate "A"
2542188
YA261
DC Distribution to Gate "B"
2542189
YA271
DC Distribution to Gate "C1 ", Gate "C2" and
2542190
Gate 01 H01-A_lHammer Driver Boarctl_
YA112
2539396
YA182
2470789
Figure 5-2. Power supply Logic Pages
5-4
(7/69)

Advertisement

Table of Contents
loading