3. Ensure that the shortening level is at the top frypot
bend for FQG100/120 fryers or top (HOT) Oil level
line for FQG80 fryers, when the oil is at its cooking
temperature.
3.1.2 Lighting the Fryer
1. Ensure the controller is in the OFF position.
2. Ensure the gas is "ON".
For CE Fryers
Placing the ON/OFF switch on the controller
in the OFF position also turns off the gas
valve. Wait five minutes before continuing
with Step 3, which will also turn on the gas
valve. NOTE: There is not a physical ON/
OFF knob on CE gas valves.
3. Ensure that the controller is switched ON by pressing the ON/OFF switch
Never use a match or taper to light pilot on this ignition system.
4. The ignition module will energize the pilot gas supply and the ignitor.
The ignitor spark will ignite the pilot gas. The presence of the pilot flame
is then proved by a flame sensor, which sends a signal to the main gas
supply, opening the valve. The controller controls the fryer after ignition.
All Frymaster fryers are tested, adjusted and calibrated to sea level con-
ditions before leaving the factory. Adjustments to assure proper opera-
tion of pilot may be necessary on installation to meet local conditions,
low gas pressure, differences in altitude and variations in gas character-
istics. These adjustments correct possible problems caused by rough
handling or vibration during shipment and are to be performed only by
qualified service personnel. These adjustments are the responsibility of
the customer and/or the dealer and are not covered by the Frymaster
warranty.
The inlet pipe at the lower rear of the fryer brings incoming gas to the pilot safety control valve,
then to the pilot and main burners. The pilot is located high in the cabinet center, at the base
of the frypot.
Top (Hot) OIL LEVEL line
Bottom (Cold) OIL LEVEL line
FQG80 Fryers
For Non-CE Fryers
After placing the ON/OFF switch on the
controller in the OFF position, turn the gas
valve knob to the OFF position.
minutes, then turn the knob to the ON position
and proceed with Step 3.
WARNING
3-3
Wait 5
to the ON position.
Pilot in normal
operation.