Troubleshooting

5-1

Troubleshooting

5-1-1

Connection Errors

Problem
The POWER indicator is not lit.
The Monitor is blank.
The Video Monitor image is not
clear.
Cannot make key inputs from the
Console.
Camera images do not appear on
the screen (for Cameras with Light
Source).
Camera images do not appear on
the screen (when a standard CCTV
lens and lighting are used).
The indicators do not turn ON (for
Cameras with Light Source).
5-1-2

Menu Operation Errors

Problem
The measurement results are not
displayed on the Monitor.
5-1-3

Parallel Interface Errors

Problem
Trigger signals (input signals) are
not received.
Signals cannot be output externally. The trigger signal has not been input.
40
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
The Power Supply is not connected properly.
The supply voltage is not 24 VDC
The power to the Monitor is not ON.
The Monitor Cable is not connected properly.
The Monitor is malfunctioning.
The power supply capacity is insufficient.
There is electrical noise entering from the power supply or cables.
The Monitor Cable is not correctly connected.
The Console Cable is not correctly connected.
The Camera Cable is not correctly connected.
The lighting cable is not properly connected to the Camera.
The lens cap has not been removed.
The Camera Cable is not properly connected.
The lens iris is opened or closed too far.
The shutter speed is not suitable.
The lighting method is not suitable.
The lighting cable is not correctly connected to the Camera.
Power is not being supplied to the F160.
When using a Camera with Intelligent Lighting, the DIP switch pins are not
set to 0.
When using an F160-S2 Camera with Intelligent Lighting, the number of
lines is not set to 484.
The F160 is not in Monitor or Run mode.
The cables are not correctly wired.
The signal line is disconnected.
The status of communications can be checked with the I/O monitor.
The F160 is not in Monitor or Run mode.
The cables are not correctly wired.
The signal line is disconnected.
The status of communications can be checked with the I/O monitor.
The F160 is not in Run mode.
Probable cause
+10%
/
.
-15%
Probable cause
Probable cause