Samson 3276-D Mounting And Operating Instructions page 25

Pneumatic actuator
Table of Contents

Advertisement

Table 3-3: Maximum effective thrusts in N
Actua-
Version
tor area
(cm²)
258
387
Type 3276-D
645
1032
258
387
Type 3276-R
645
1032
With a signal pressure of 80 psi (5.5 bar)
1)
EB 8318 EN
Bench
range
26
(bar)
0.2 to 1
11594
 1)
0.4 to 2
8918
 1)
0.2 to 1
17390
 1)
0.4 to 2
13377
 1)
0.2 to 1
31660
 1)
0.4 to 2
27646
 1)
0.2 to 1
52082
 1)
0.4 to 2
47088
 1)
0.2 to 1
53509
 1)
0.4 to 2
49228
 1)
0.2 to 1
535
0.4 to 2
1070
1.4 to
3567
2.8
0.2 to 1
803
0.4 to 2
1605
1.4 to
5351
2.8
0.2 to 1
4013
0.4 to 2
8026
1.4 to
13377
2.8
0.2 to 1
7848
0.4 to 2
15696
1 to 3.1
24971
0.2 to 1
9275
0.4 to 2
17836
0.9 to
29965
3.5
Design and principle of operation
Travel (mm)
51
75
28984
 1)
22295
 1)
49228
46375
 1)
 1)
41380
35673
 1)
 1)
51369
49942
 1)
 1)
45661
42807
 1)
 1)
1338
2675
8918
4994
2140
9988
4281
17836
10702
7135
5708
14269
11415
24971
19977
95
127
48515
46375
 1)
 1)
39953
35673
 1)
 1)
4281
2140
8561
4281
15696
9275
3-11