Follett Condensing Unit - Follett Horizon Elite HCF1412R Operation And Service Manual

Table of Contents

Advertisement

Follett Condensing Unit – F1412CU
W1 Width
D1 Depth
H1 Height
Electrical
Minimum circuit ampacity
Maximum overcurrent protection
Outdoor condensing unit operating limits
(air temperature)
Maximum refrigerant line run length
Maximum line rise above evaporator
Maximum refrigeration line drop without oil trap
Refrigerant charge
Approximate ship weight
Approximate net weight
HCF1412R, HCF1412K
1412 three phase
D1
W1
Horizon Elite 1412 series
39.6" (100.6 cm)
28.2" (71.6 cm)
26.0" (66.0 cm)
three phase – 208-230/60/3 (Emerson/Copeland)
three phase – 12A
three phase – 20A
min –20 F (–29 C)
max 120 F (49 C)
100' (30,5 m)
35' (10,7 m)
15' (4,6 m)
8 lb
three phase – 265 lbs (120.2 kg)
three phase – 230 lbs (104.3 kg)
H1
9