  • Page 1 Instructions for Use LMM56800 Large Monitor Manager Important Please read the safety information and all information delivered with the product carefully to familiarize yourself with safe and effective usage.
  • Page 2: Legal Information

    Use of EIZO products WARNING EIZO products may only be used for the applications described in the catalog and in the relevant tech- nical documentation. If products and components from other manufacturers are used, these must be recommended or approved by EIZO. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    6.5.3 Logging in and out ...................  29 6.5.4 Reboot and shutdown ................ 30 "Base settings" (extended) sidebar ................ 30 6.6.1 Settings .....................  31 6.6.2 Setting the network connection .............. 33 6.6.3 Changing the password ................ 34 LMM56800 Instructions for Use, 10/2019...
  • Page 4 10.1 View from front, top, and side ................. 61 11 Spare parts / accessories .................... 62 11.1 Accessories ...................... 62 12 Appendix .........................  63 12.1 Markings and symbols .................... 63 12.2 Information on electromagnetic compatibility (EMC) .......... 64 12.3 FCC Declaration of Conformity................ 68 LMM56800 Instructions for Use, 10/2019...
  • Page 5 Table of contents 12.4 China RoHS (Restriction of Hazardous Substances) .......... 69 12.5 Environmental protection .................. 70 12.6 Warranty ......................... 70 12.7 Additional devices.................... 71 12.8 Repairs ........................ 71 12.9 Contact ........................ 71 12.10 Trademarks...................... 71 Index .......................... 72 LMM56800 Instructions for Use, 10/2019...
  • Page 6: Introduction

    1.1 Contents of this document This document explains the functionality and the approved use of the Large Monitor Man- ager LMM56800. To ensure clarity, it does not contain all detailed information on this prod- uct. The contents of this document are neither part of a previous or existing agreement, commit- ment or legal relationship, nor does it modify such.
  • Page 7: Safety Information

    2 Safety information 2.1 General safety instructions Correct and safe operation of EIZO devices assume professional transport, storage, installa- tion, and connection, as well as careful operation and service. The devices may only be used for applications for which they are intended.
  • Page 8 Connection in China Only use power cables approved for China. These power cables are identified by the labels "CCC" or "CQC". Observe the country-specific regulations Observe all regulations of the country in which the device is used. LMM56800 Instructions for Use, 10/2019...
  • Page 9 If the device is brought into a room with a higher or rising temperature, condensed water will form in and on the device. Do not switch on the device until the condensed water has evaporated. Other- wise, the device could be damaged. LMM56800 Instructions for Use, 10/2019...
  • Page 10 Note that monitors can fail as a result of aging, and that image properties such as brightness, con- trast,and color value can change. Do not touch the monitor screen Due to mechanical pressure or electrostatic discharges, touching the screen can result in brief distur- bances to the image. LMM56800 Instructions for Use, 10/2019...
  • Page 11: Product-Specific Safety Notes

    It is the user's responsibility to protect this system against viruses and attacks from the Internet or other devices in this system LMM56800 Instructions for Use, 10/2019...
  • Page 12: Description

    2 US, EU power cable each • 2 DP modules (DisplayPort to DVI converter) • 2 holder for installing the DP modules on top of the LMM56800 • 3 Y cables (adapter for connecting VGA and DVI-D to DVI-I) •...
  • Page 13: Features

    Flexible arrangement of different video sources The LMM56800 allows up to 26 different video sources to be displayed on one monitor si- multaneously. The video sources can be displayed in different scales or cropping areas. This means that the workflow can be simplified in the control room or examination room for example, and several work stations can be combined into one.
  • Page 14: Setup And Installation

    This could result in a short circuit when switching on the device, damaging it. • Wait until the condensed water has evaporated, including that inside the device, before you switch it on. This can take several hours. LMM56800 Instructions for Use, 10/2019...
  • Page 15: Positioning As A Desktop Device

    3. Connect the DP cable of the DP module for the right DVI channel to DP output 1B. 4. Connect the USB cable of the DP module to the USB port ("PWR") of the LMM56800. 5. Connect the DVI modules and cables of the TDL Dual Link Sets according the color cod- ing on the DP module.
  • Page 16: Installing The Y Cable

    Note: The labels attached to the Y cable indicate the sockets into which the connectors are to be inserted. 2. Hand tighten the screws of the connector. You do not need a tool. 3. Repeat the steps for installing the Y cable for inputs 10/11 and 19/20 of LMM56800. Fig.: Installed Y cable...
  • Page 17: Installing In A Rack

    Setup and installation 4.5 Installing in a rack 4.5 Installing in a rack The LMM56800 can be installed in a 19" rack. Note The mounting brackets for installing the Large Monitor Manager are not in the scope of de- livery. CAUTION Installing devices in the rack •...
  • Page 18: Connecting

    Follow all shielding measures in accordance with local EMC directives. If these guidelines are not observed, device malfunction may result. NOTICE Disconnecting from line power Always set the power switch to "Off" before disconnecting the device from power. Other- wise the device could be destroyed. LMM56800 Instructions for Use, 10/2019...
  • Page 19 • Externally connected cables can represent a trip hazard. Make sure that all incoming cables are safely routed. • If the device offers strain relief mechanisms for the cables, use them to prevent unin- tended loosening of connected cables. LMM56800 Instructions for Use, 10/2019...
  • Page 20: Connection Panel

    5 V power supply of the DP modules. Power input IEC 60320 C14 input Input power supply On/Off Power switches of the redun- Switching on / switching off the device dant power supplies Display 1 / 2 Not used LMM56800 Instructions for Use, 10/2019...
  • Page 21: Connection Procedure

    If you assign the connection panels 2, 9, 11, 18, 20, and/or 27, use a com- mercially available VGA cable. Connecting to the network The LMM56800 operates using a network. A network connection has to be established be- tween RJ45 connector N1 of the LMM56800 and a PC. •...
  • Page 22: Input Signals

    Do not use any other fuse. The LMM56800 has two redundant power supply units. If one power supply unit fails, the other power supply unit ensures continuous operation of the LMM56800.
  • Page 23 The minimum v-blank pixels has to be 4. Image refresh rates A minimum pixel clock of 16 MHz is required. EIZO recommends a refresh rate of 60 Hz because the video output signal on the LMM56800 has an image refresh rate of 60 Hz. Video bandwidth The LMM56800 has the following input bandwidth restrictions: •...
  • Page 24: Configuration And Operation

    1:1, with a border, or as a cropping area. Each instance can be assigned to one or more windows and layouts. Remote operation Operation of the LMM via LAN or WLAN. LMM56800 Instructions for Use, 10/2019...
  • Page 25: Basic Icons

    The instance is active, but there is no video signal The instance was deleted. Insufficient resources available. The miniature thumbnail of the instance has not yet been configured or was deleted. The miniature thumbnail of the instance cannot be displayed. LMM56800 Instructions for Use, 10/2019...
  • Page 26: Setting Up Operation

    Configuration and operation 6.3 Setting up operation 6.3 Setting up operation The LMM56800 operates via remote access. Remote access is possible via LAN or WLAN The following steps are necessary to set up the connection: Note The Large Monitor Manager has to be switched on and connected to the network.
  • Page 27: Overview Of The Sidebars

    Changes the language in the dialog windows Opens the dialog window for logging on as "Service" (administrator) or "Ad- vanced" (user with advanced rights). The Large Monitor Manager reboots. The Large Monitor Manager shuts down. LMM56800 Instructions for Use, 10/2019...
  • Page 28: Calling Up System Information

    See also chapter "Setting the network connection". The Large Monitor Manager has three IP addresses when DHCP is used. Otherwise it has two IP addresses. Default setting: IP address 192.168.1.10 Fall-back IP address: 169.254.213.44 (cannot be changed) LMM56800 Instructions for Use, 10/2019...
  • Page 29: Changing The Language Setting

    To activate the standard user role again, click Note Changing the password To define a new password for a user, log in using the appropriate role and open the "Change password" dialog box (see also Changing the password [} 34]). LMM56800 Instructions for Use, 10/2019...
  • Page 30: Reboot And Shutdown

    To reset all passwords to the standard password, click and enter the master pass- word. The master password depends on the MAC address of the LMM56800. It can only be cre- ated by EIZO. Please ask Service for the master key. Password...
  • Page 31: Settings

    6.6 "Base settings" (extended) sidebar To open the "Base settings (extended)" sidebar, move the mouse pointer to the right edge of the screen. 6.6.1 Settings Click the "System settings" button to open the following dialog window: LMM56800 Instructions for Use, 10/2019...
  • Page 32 Click the color box to change the color. Default setting: green Double-click (ms) Set the double click speed here. Default setting: 500 ms Active window Border color The border color of an active window can be defined here. Default setting: green LMM56800 Instructions for Use, 10/2019...
  • Page 33: Setting The Network Connection

    The gateway and DNS server are assigned automatically and cannot be changed. • The MTU value is assigned automatically and cannot be changed. MTU (Maximum transmission unit) specifies the maximum size of the data packets that can be sent in the network. LMM56800 Instructions for Use, 10/2019...
  • Page 34: Changing The Password

    Setting the system time [} 36] 6.6.3 Changing the password Two passwords are assigned as default for the LMM56800. For the administrator ("Service") the password "super" and for the user with expanded rights B ("Advanced") the password plus". If you want to change one of these passwords you have either log on as administrator or as user with extended rights (see also Logging in and out) Only the password for the user logged in at the time is changed.
  • Page 35: User Permissions

    When you start the Large Monitor Manager you are logged in as the default user. Rights The following rights are assigned to the roles "Default user" and "Default user with extended rights" (Advanced). The administrator has all rights. LMM56800 Instructions for Use, 10/2019...
  • Page 36: Setting The System Time

    2. Enter the server address in the "NTP Server" field. 3. Click "OK". Without NTP server 1. Incrementally change the date and time with the arrow keys until the required values are displayed. 2. Click "OK". Restart the device to apply the changes. LMM56800 Instructions for Use, 10/2019...
  • Page 37: Updating The Firmware

    • Perform a firmware update in consultation with your local distributor or on the recom- mendation of EIZO only. • Only use firmware updates released by EIZO to ensure proper function of the Large Monitor Manager. To update the firmware proceed as follows : 1.
  • Page 38: Backup/Restore

    The user data are compressed in a zip file. A corresponding message indi- cates that the backup is complete. If you selected "Download" in remote access, a dialog is displayed for se- lecting the backup location. Back up the data to the required location. LMM56800 Instructions for Use, 10/2019...
  • Page 39: Creating A Logbook

    6.6.8 Creating a logbook Note The information in the logbook is only intended for EIZO support personnel, and can only be evaluated by specialists from EIZO. To create the logbook for EIZO support : 1. Click the "Logbook" button in the "Basic settings" (extended) sidebar.
  • Page 40: Input Configuration" Sidebar

    If you click this button with the left mouse button, the selected instance is deleted. If the instance was assigned to a window, the symbol appears in the window: LMM56800 Instructions for Use, 10/2019...
  • Page 41 To adjust the LUT for the connected monitor, proceed as follows: 1. Double-click the "Monitor 1" button in the "Input configuration" sidebar. 2. In the displayed dialog window select the required LUT. 3. Close the dialog window. LMM56800 Instructions for Use, 10/2019...
  • Page 42: Configuring Digital Video Inputs

    Use the arrow keys to select the EDID setting for the respective video input. The EDID setting specifies the resolution that will be provided by the graphics card of the video source. You can select the following EDID data: LMM56800 Instructions for Use, 10/2019...
  • Page 43: Configuring Analog Video Inputs

    SMPTE test pattern and set the contrast such that the picture areas with 95 % and 100 % gray values visibly differ. Horizontal The horizontal position of the displayed image can be set down to a pixel. position Setting range: 0 - 100 % Default setting: 50 % LMM56800 Instructions for Use, 10/2019...
  • Page 44 Select EDID Here you can define the EDID data for the selected video. This specifies resolution to be provided by the graphics card of the video source. You can select from the following EDID data: LMM56800 Instructions for Use, 10/2019...
  • Page 45: Creating And Configuring Instances

    1. Left-click the video input ① for which an instance should be configured. 2. To configure an instance, double-click the miniature thumbnail of the instance ②. Alternatively, click The "Instance configuration of a video input" dialog window is displayed. LMM56800 Instructions for Use, 10/2019...
  • Page 46 The video input for which the instance is created appears as default. To assign Video input the same settings to a different video input, use the drop down list. Default setting: The selected video input LMM56800 Instructions for Use, 10/2019...
  • Page 47 Note: Alternatively, you can load a symbol, for example from a USB stick. Click the button. To delete the thumbnail, click the button. Keyboard/mouse Not available for LMM56800. settings To view only a certain part of an instance, you can define the cropping area as Image cropping enabled follows: Enable image cropping.
  • Page 48 Setting range: 1 - 10 pixels wide Default setting: 1 pixel Border sides Set the sides on which a border is to be displayed. To do this, click on the indi- vidual border sides in the thumbnail. Default setting: complete border LMM56800 Instructions for Use, 10/2019...
  • Page 49: Layout" Sidebar

    Description Resets the user-defined settings in all layouts to the original values. This is only possible if the settings have not already been saved. Creates a new layout. Saves the user-defined settings in all layouts. LMM56800 Instructions for Use, 10/2019...
  • Page 50: Edit Layouts

    A toolbar is displayed in the upper right corner of each window in the layout. Use the tool- bars to edit the windows. LMM56800 Instructions for Use, 10/2019...
  • Page 51: Editing The Window In The Selected Layout

    Opens the menu for editing the instance in this window. The size of the window cannot be changed if the pin is set. It can only be deleted or shifted, and the created instance in this window can be edited. LMM56800 Instructions for Use, 10/2019...
  • Page 52 To prevent this, set individual windows with the pin. • A field in each upper left corner displays the position of the window in pixels. If the infor- mation window is displayed above the window, its height is taken into account. LMM56800 Instructions for Use, 10/2019...
  • Page 53: Instances" Sidebar

    5. To save the layout, in the "Layout" sidebar click Note When switching between layouts, all changes are retained, but are not automatically saved. When the LMM56800 is rebooted or switched off, all unsaved changes are lost. LMM56800 Instructions for Use, 10/2019...
  • Page 54: Status Window

    Saving the device configuration on memory media external to the Large Monitor Man- ager • Reading the log file • Saving the current screen content • Displaying text fields Software distribution is available from EIZO. Contact your local distributor with any ques- tions. LMM56800 Instructions for Use, 10/2019...
  • Page 55: Operation

    This means, for example, it is possible to exchange instances. Changing the layout To switch the layout: 1. In the address line of the web browser enter "<IP address of the LMM56800>". The standard interface opens. 2. Click the required layout.
  • Page 56: Cleaning And Maintenance

    Cleaning the fans The device is equipped with fans. Depending on the environment, these may become dirty. The fans may only be cleaned by EIZO. Ensure that the vents are unobstructed. Ensure that the vents for air intake and exhaust are not covered.
  • Page 57: Troubleshooting

    Green when all supplies are turned on No measures. and are running Red when one power supply is not con- Check power connection, power switch and nected or fails. LED of power supply, replace power supply if necessary LMM56800 Instructions for Use, 10/2019...
  • Page 58: Troubleshooting

    Connect the DP cable of the DP module for of the image are shown nected incorrectly. the left DVI channel to DP output 1A and interchanged. the DP cable of the DP module for the right DVI channel to DP output 1B. LMM56800 Instructions for Use, 10/2019...
  • Page 59: Technical Specifications

    2 via DP modules (DisplayPort to DVI converter) MHz] Output resolution 3840 x 2160 (QFHD), 60 Hz 1920 x 2160 x 2, 60 Hz Interfaces Ethernet interface RJ45 [1 Gbit/s] Voltage outputs USB power supplies for DP modules Number of USB ports (for future purpose) LMM56800 Instructions for Use, 10/2019...
  • Page 60: Power Supply

    This product has been assigned a CE marking in compliance with the stipulations of EU di- rectives 2014/30/EU, 2014/35/EU, and 2011/65/EU. Safety standards EN 60950-1 UL60950 CAN/CSA - C22.2. No. 60950 Protection class Protection class I Degree of protection IP20 in accordance with DIN 40050 LMM56800 Instructions for Use, 10/2019...
  • Page 61: Dimension Drawings

    Dimension drawings 10.1 View from front, top, and side 10 Dimension drawings All dimensions in mm 10.1 View from front, top, and side Fig.: LMM56800 dimensioned drawings LMM56800 Instructions for Use, 10/2019...
  • Page 62: Spare Parts / Accessories

    This monitor supports the required resolution of 8MP (3840 x 2160) and has been tested and released with the LMM56800. DVI Transmission Link For larger distances between the video source and LMM56800, we recommend using the TDL3600 DVI transmission link. To connect a monitor over a long distance the TDL3600-DL transmission link can be used.
  • Page 63: Appendix

    Symbol for protective ground (ground) "On" symbol (voltage). "Off" symbol (voltage). Input for service calls. Symbol for USB. DVI output signal. Symbol for direct current. Symbol for network connection. Symbol for "Comply with the instructions for use". LMM56800 Instructions for Use, 10/2019...
  • Page 64: Information On Electromagnetic Compatibility (Emc)

    Information and manufacturer’s declaration – electromagnetic radiation The LMM56800 Large Monitor Manager is intended for use in the electromagnetic environments noted below. The customer or user of the LMM56800 Large Monitor Manager has to ensure that the device is used in such an environment. Emissions test Compliance Electromagnetic environment –...
  • Page 65 Information and manufacturer’s declaration – electromagnetic radiation The LMM56800 Large Monitor Manager is intended for use in the electromagnetic environments noted below. The customer or user of the LMM56800 Large Monitor Manager has to ensure that the device is used in such an environment. Interference im-...
  • Page 66 Information and manufacturer’s declaration – electromagnetic radiation The LMM56800 Large Monitor Manager is intended for use in the electromagnetic environments noted below. The customer or user of the LMM56800 Large Monitor Manager has to ensure that the device is used in such an environment. Interference IEC/EN 60601...
  • Page 67 Recommended minimum distance between portable and mobile RF communications devices and the LMM56800 Large Monitor Manager The LMM56800 Large Monitor Manager is intended for use in an electromagnetic environment in which interference due to electromagnetic radiation is controlled. The customer or user of the LMM can help prevent electromagnetic interference by maintaining the recommended minimum distance between portable and mobile RF communications devices (trans- mitter) and the monitor as shown below.
  • Page 68: Fcc Declaration Of Conformity

    Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note Use the attached specified cable below or EIZO signal cable with this monitor so as to keep interfer- ence within the limits of a Class B digital device. •...
  • Page 69: China Rohs (Restriction Of Hazardous Substances)

    Appendix 12.4 China RoHS (Restriction of Hazardous Substances) 12.4 China RoHS (Restriction of Hazardous Substances) LMM56800 Model: 6GF60301AB## (##=00...99) 根据SJ/T11364-2014《电子电气产品有害物质限制使用标识要求》特提供如下有关污染控制 方面的信息。 The following product pollution control information is provided according to SJ/T11364-2014 Marking for the restriction of the use of hazardous substances in electrical and electronic product.
  • Page 70: Environmental Protection

    Opening of the housing, or electrical or mechanical changes on or in the device, result in cancellation of the warranty. For warranty details, please contact the sales partner from whom you purchased the product. These warranty conditions are neither extended nor lim- ited by the contents of this instruction manual. LMM56800 Instructions for Use, 10/2019...
  • Page 71: Additional Devices

    12.10 Trademarks The EIZO Logo is a registered trademark of EIZO Corporation in Japan and other countries. EIZO is a registered trademark of EIZO Corporation in Japan and other countries. RadiForce is a registered trademark of EIZO Corporation in Japan and other countries.
  • Page 72: Index

     57 Reboot  30 Rights  35 Factory setting  38 Roles  35 Fan cleaning  56 Firmware update  37 General safety instructions  7 Input configuration  40 Input signals  22 Installation location  14 Instance  45, 53 Intended use  12 LMM56800 Instructions for Use, 10/2019...
  • Page 73  36 Technical specifications  59 Troubleshooting  58 User  6 User data  38 User rights  35 Ventilation  14 Video bandwidth  23 Video input Analog  43 Digital  42 Instance  45 View Management  55 Warranty  70 Window process  50 LMM56800 Instructions for Use, 10/2019...
  • Page 74 Carl-Benz-Straße 3 76761 Rülzheim Germany Instructions for Use, 10/2019 LMM56800 1046975-003 Copyright © 2019 EIZO GmbH. All rights reserved.