  • Page 1 Large Monitor Manager Setup LMM0802 & LMM56800...
  • Page 2 LMM system - Configurations Quick Start Guide ▪ LMM0802 Set up and configuration ▪ Configuration ▪ General Setup ▪ Connection example ▪ Configuring the input signals ▪ Creating Layouts ▪ Network Settings ▪ System control (user interface)
  • Page 3 1. Web Browser via a network ▪ Equipment required: ▪ Monitor (mandatory) ▪ LMM0802 (mandatory) ▪ Standard PC with a web browser installed ▪ Monitor with minimum 1280 x 1024 screen resolution ▪ Network switch if more than one device is connected to the LMM (optional) 2.
  • Page 4 General Setup – Web Browser IP address: 169.254.213.125 Web browser: 169.254.213.144/config PC for configuration LMM0802 LS580W, LX550W IP address: 169.254.213.144 Video Connecion Ethernet LAN Connection...
  • Page 5: General Setup

    General Setup – 2 PC for configuration LMM56800 LS580W Source 1 Source 2 Source 3 Source n User Interface Video Connection e.g: CID1000P Ethernet LAN Connection 1G-b: LMM system - Configurations...
  • Page 6: Connection Example1

    Connection Example1 LS580W CID1000P IP address: 169.254.213.11 IP address: 169.254.213.1 Ethernet (cross) for maintenance IP address: 169.254.213.44 External interface: PC or laptop 1G-b: LMM system - Configurations...
  • Page 7: Connection Example2

    Connection Example2 1G-b: LMM system - Configurations...
  • Page 8: Computer Ip Settings

    Computer IP Settings...
  • Page 9 Web Browser Control of LMM ▪ Entering the configuration menu ▪ Enter the IP Address of the LMM in the address bar of a web browser Note Recommended browsers (IE can cause unusual difficult to understand problems), instead use: Chrome Mozilla Firefox Version 10 or higher...
  • Page 10 Error when using IE...
  • Page 11 General Setup – Standalone Connect a keyboard and mouse to connection panels X1 ... X6. Confirm you have blue mouse cursor on monitor(s) connected to the LMM output.
  • Page 12 Log on as "Administrator" Open Base settings“ sidebar. Click “ “ Select “Service” Input “super” as Admin password. Base Settings menu activated.
  • Page 13: User Interface Overview

    User Interface Overview ③ Sidebar "Layout"  ④ Sidebar "Instances"   Log in  ① Sidebar "Base settings“ ② Sidebar "Input configuration” Basic Operation for sidebar Sidebar pops up when mouse cursor approach to each sides. Click “pin” icon to keep the sidebar opened.
  • Page 14 Configuring the input signal Connect the video signals from the sources to the LMM Open the "Input configuration” Sidebar of the LMM. Confirm if the port shows green sign. Signal info can be checked by moving cursor over the port. Symbol legend: Channel is not active Channel is active, but the signal information can not be read.
  • Page 15 Configuring the digital input signal Double-click left on the port where input signal is connected. Video configuration window appears on the center of the screen. Image Preview here Define EDID (Resolution) of this input port by selecting from the pull-down menu. Click OK to close the Video configuration window.
  • Page 16: Creating Instances

    ✓ Defined presentation of a video signal of a video source within a window of a layout. For each video input of the LMM0802, multiple instances can be displayed with different presentations, e.g. 1:1, with a border, or as a cropping area.
  • Page 17 Creating instance Name of the source signal Create/delete miniature thumbnail for each instance. Activate KVM function, see the slide (KVM settings). Activate this option when displaying vital functions or ECG images in a layout smaller than 1:1. Check these boxes to show the signal name Check this to make advanced on the screen and to...
  • Page 18: Creating Layouts

    Creating layouts New Layout Open “Sidebar layout”, click “ “ to create new layout. Specify the name of the new layout One single window will be open as a new layout. Tool icons will be shown on the top right. (see next page for details)
  • Page 19 Creating layouts Delete Split Expand Blank...
  • Page 20 Creating layouts Fixed Makers If Original signal resolution Is 1920 x 1200… Banner position Change the window size by moving green makers. Expand the region to 1920 x 1200. Go to Instance config.
  • Page 21 Assigning instances to layout "Instances" Sidebar Instances can be assigned to the windows of the selected layouts. (Drag and drop operation) Save Layouts All the instances created are listed on the “Instances” sidebar.
  • Page 22 Other layout controls Icon Description Click the button to edit the layout. You can save layout changes. To do this, click on the button. You can define a layout as the default layout. To do this, click on the button. You can duplicate the layout.
  • Page 23: Kvm Settings

    KVM Settings Video Input/USB Configurations USB 1 Video 1 LMM0802 USB 2 Video 2...
  • Page 24: Network Settings

    Network settings Open “base settings” sidebar. Click “Network Settings”. Open the Menu Network settings...
  • Page 25 Backup/Restore In a backup/restore, you can back up and restore user data and restore the factory defaults. To open the "Backup/Restore" dialog box, click the "Backup/Restore" button in the "Base settings" (complete) sidebar. Function Description The user-defined settings are backed up. Click the Backup User Data"...
  • Page 26: Update Firmware

    Update Firmware The new firmware file can be imported locally using a USB memory stick. The file name always starts with "UpdateFile" and has the file extension "ZIP". 1. Click the "Update firmware" button. The "Update firmware" dialog box appears. 2.
  • Page 27 The CID1201P-EU is shipped with default start page of the browser for LMM56800. Please follow these steps to change default start page of the browser for LMM0802, LMM0804. Procedure located in “7.3 Change home page” section of CID1000P Instructions for Use, 10/2014 manual.
  • Page 28 LMM System Information...
  • Page 29 LMM56800 Quick Start Guide...
  • Page 30 Configuring the input signal – 1 Connect the video signals from the sources to the LMM Note the input numbers on the back of the LMM, the video sources have been connected Input from the sources Output to the Monitor Note: Receiver of TDL (DVI Transmission Link) require 5 V power supply Enter the configuration Menu of the LMM (see General Setup)
  • Page 31 Configuring the input signal – 2 . Select the input to . Check to enable configure the channel if necessary and press „apply“ . Press „Use current hw resolution“ to recognize the resolution from Note: the source If 0x0 is displayed, please check if the source signal is present...
  • Page 32 Configuring the input signal – 3 It is possible to display the a name on the screen for each source as well as a frame around the source window Name of the source signal Select the font type for the name Check these boxes to show the signal name on the screen...
  • Page 33: Creating Layouts

    Creating layouts – 1 Enter the configuration Menu of the LMM (see General Setup) Click on the “Arrangement” button on the screen 1G-b: LMM system - Configurations...
  • Page 34 Creating layouts – 2 Schematic view of the monitor to place the source Configured sources that can be displayed on the monitor windows on . Select the sources to be shown on the . With the „Save as default monitor. set“...
  • Page 35 Creating layouts – 3 For precise positioning of the window enter the position of the upper left corner of the window. You can also use the arrows for Enter the number of pixels you want to pixel wise movement. crop from the source window. From the top, the bottom, the left or the right border.
  • Page 36 Network settings Enter the configuration Menu of the LMM (see General Setup) Click on the “Configuration” drop down Menu (arrow) on the screen Open the Menu Network settings 1G-b: LMM system - Configurations...
  • Page 37 Network settings: General It is possible to change the LMM network settings in order to integrate it into an existing LAN network Click on the tab Network of the “Network Setting” Menu Type in the desired IP Address for the LMM Click The “save”...
  • Page 38 Network settings: FTP server It is possible to configure an FTP connection to the LMM in order to backup and restore the configuration or to do update the system. Click on the tab Network of the “Network Setting” Menu Type in the defined FTP settings (please refer to the LMM SW Upgrade guide for the FTP server setup procedure: Click The “save”...
  • Page 39 System Control – CID1201P-EU ▪ The CID 1201P-EU will automatically find the LMM and show the layouts after boot up once connected to network ▪ Use CID1201P-EU to change layouts during LDS operation Standard Interface View Management Interface...
  • Page 40 System Control – Other It Is also possible to control the system through any other device hosting a web browser Connect the device into the LMM Network. Open the web browser software and type in following URL: http://LMMIPaddress For example: http://169.254.213.144...

This manual is also suitable for: