Feed Water Supply Installation

Tapping into the COLD WATER line
CAUTION:
The water supply to the unit MUST be connected to the COLD WATER
LINE. HOT WATER will severely damage your RO System.
1. Turn off the Cold Water Line via the Cold Water Supply Valve (CWSV) under
the sink. Open the kitchen faucet to release any pressure and make sure the
water has stopped before proceeding to the next step. Get a towel or bucket to
catch any water drips. Disconnect the Kitchen Faucet Connector (KFC) pipe
from the CWSV.
2. Check to make sure the O-ring is seated inside the Feed Water Adapter
female end, and twist it onto the CWSV. Tighten it using a wrench or pliers.
3. Twist the KFC onto the male end of the Feed Water Adapter. Turn the handle
of the Feed Water Adapter to the perpendicular OFF position. Turn on the
CWSV slowly, and ensure you are getting a proper seal.
4. Connect the 3/8"
Feed Water Adapter with Bushing to convert 3/8" COMP to 1/2" NPT
5. Connect the feed water tubing to the RO system. Once the feed water adapter
has been installed, connect the tubing (RED) to the first stage (clear housing)
of the RO system.
iSpring Water Systems
RED
tubing to the Feed Water Adapter.