1. Turn on both the cold water supply and the undersink feed water valve, and
close the tank ball valve. If any leaks are noted, turn off the valve and correct
before proceeding.
2. Open RO faucet for continuous flow.
3. Check the system for leaks; tighten where necessary.
4. After five minutes, the water will start to drip out of the RO faucet. Let it drip for
about 10 minutes and then flip the handle to the closed position. Turn on the
tank ball valve. It will take one to three hours for the storage tank to fill,
depending on the local water pressure.
WATER PRODUCED BY YOUR NEW SYSTEM.
5. After the tank is full (you will hear the water stop), flush the system by placing
the RO faucet in the open position until the water is completely discharged.
6. Upon complete discharge of the storage tank, turn the RO faucet's handle to
the closed position and let the refilling process begin. This process could take
one to three hours to complete.
7. After the second tank is filled, the pure water is ready for you to enjoy.
8. Check for leaks daily during the first week of use and periodically thereafter.
9. You may notice that the water is milky colored during the first week. This is an
indication of air bubbles in the water; it is normal and safe to drink.