Install The Tank Ball Valve - Ispring PH100 Installation Instructions & Owner's Manual

Table of Contents

Advertisement

1. Choose a spot on the drain pipe that is convenient for installing the drain
saddle. A horizontal pipe is recommended to minimize the dripping sound.
2. Drill a 1 /4" hole in the drain pipe, and paste the black sticky pad around the
hole.
3. Cut the BLACK tubing end to make a 45 degree angle. Insert the tubing into
the 1/4" hole in the drain pipe, install the back plate, and tighten the two
screws with hex nuts while the tubing remains in the hole.
4. Insert Lock Clip. Pull the tubing lightly to make sure it is secure.

Install the Tank Ball Valve

NOTE: Do not tamper with the air valve on the lower side of the storage
tank. It has been preset at 8–10 psi by the manufacturer.
1. Unplug the plastic cap on the top of the tank.
2. Connect the ball valve to the thread. Make sure it is tight, but not overly tight.
3. Place the storage tank in the desired location either horizontally or vertically.
4. Connect the
WHITE
tank ball valve.
(See 5-Stage RO system diagram.)
5. Turn the tank ball valve off.