Output Modes; Fixed Transitions; Cosine Transitions; Linear Transitions - HP 8112A Operating, Programming And Servicing Manual

50 mhz programmable pulse generator
Table of Contents

Advertisement

Output Modes

Complement
Disable

Fixed transitions

Cosine transitions

Linear transitions

Inputs and Outputs

External Input

Control Input Bandwidth

Trigger Output

Selectable
Disconnects output, default at switching on.
Limit
Implements present output levels as output limits.
5 ns from 10% and 90% amplitude, 3.5 ns from 20% to 80%
amplitude
Up to 25% faster between 10% and 90% of amplitude than linear
transitions
Threshold level
Minimum amplitude
Maximum Input voltage
Minimum pulse width
Input impedance
Trig slope
Input voltage limits
Input impedance
High level
Low level
Duty cycle
Output impedance
Propagation Delay
(EXT INPUT to TRIG
OUTPUT)
on/off
500 mV (p-p)
10 ns
10 kR
off, pos, neg, both (Trigger and Ext
Width only)
1 kHz
10 kR
o v
50%
50 R
25 ns
Specifications