PERFORMANCE TEST RECORD: Hewlett-Packard 8112A 50 MHz Pulse Generator
Serial No: ______--------------------- Report No: __---_----__---__--------- Date: _------------
Transition Times
Transition Period Leading Edge Trailing Edge Minimum MEASURED Maximum Uncertainty
Fixed
100 n s 4.5 n s
100 n s 6.5 n s
Linear
Period
500 ps
2 ms
5 ms
5 ms
50 ms
Low
Low-Level
-0.1 v
-0.5 v
-1.0 v
-5.0 v
-8.0 v
Fast
4.5 n s
6.5 n s
Leading Edge Trailing Edge
500 ns
500 ns
100 PLs
100 /B
500 , L Ls
500 ps
999 ps
999 ps
1 ms
1 ms
10 ms
10 ms
PERFORMANCE TEST RECORD Page 5 of 6
MEASURED Maximum
-0.056 V
-0.44 v
-0.92 v
-4.76 V
-7.64 V
4.675 n s
MEASURED MaximUm
473 ns
95 #us
475 jLs
949 ps
0.95 ms
9.5 ms
Uncertainty
-0.144 v
-0.56 V
-1.08 V
-5.24 V
-8.36 V
5.0 ns (typ)
8.825 n s
Uncertainty
527 ns
105 #us
525 ps
1.05 ms
10.5 ms
Testing Performance 8-37