PROCESSOR TECHNOLOGY CORPORATION
8KRA STATIC READ/WRITE MEMORY MODULE
SECTION III
3.4
MEMORY DISABLE OPTION (AREA C)
Select the phantom disable option only if the 8KRA is to be
used at address zero with a Processor Technology ALS-8 Firmware Module.
Selection is accomplished by installing a jumper (#24 bare wire is
recommended) between the two Augat pins in Area C .
With th is jumper
installed, the 8KRA will be disabled by the signal, PHANTOM, which is
supplied by the ALS-8 on Bus Pin 67.
If the 8KRA is not to be used at address zero with the ALS-8,
DO NOT install a jumper in Area C.