RX Main VCO Test (Continued)
Continued
from previous
Page
Check that the voltage
at R603 is between
0.5 and 2.1 Vdc.
Is the
voltage between
0.5 and 2.1 Vdc
?
Pass
Check that the TCXO oscillator
frequency is 33.6 MHz +84 Hz.
Ensure the correct band select is chosen.
For 800 band, U300 pin 8/C302 is low and
pin 7/C304 is high. For 900 band U300 pin
7/C304 is low and pin 8/C302 is high.
Is the
TCXO frequency
within range
?
Pass
Check for a problem in the
VCO module. Replace the
module and test again.
6880401P26-O
Is
Fail
the voltage railed
high (>2.1 Vdc)
?
Check for opens, shorts, or missing
components in the loop filter. Ensure SEL1
and SEL2 voltage levels are programmed
properly.Ensure SLEDGEHAMMER
Check for a problem in
the TCXO oscillator
Fail
circuit. Refer to the
TCXO Oscillator
flowchart.
TROUBLESHOOTING: RX Main VCO Test
There is no issue with
the control voltage.
Is
the voltage
Fail
railed low
(<0.5 Vdc)
?
Pass
Correct band is
selected.
commands are proper.
Fail
69